Internet Engineering Task Force (IETF)                          D. Black
Internet-Draft
Request for Comments: 8014                                      Dell EMC
Intended status:
Category: Informational                                        J. Hudson
Expires: March 24, 2017                                      Independent
ISSN: 2070-1721                                               L. Kreeger
                                                                   Cisco
                                                             M. Lasserre
                                                             Independent
                                                               T. Narten
                                                                     IBM
                                                      September 20,
                                                            October 2016

  An Architecture for Data Center Data-Center Network Virtualization Overlays over Layer 3
                                 (NVO3)
                        draft-ietf-nvo3-arch-08

Abstract

   This document presents a high-level overview architecture for
   building data center network virtualization overlay data-center Network Virtualization over Layer 3 (NVO3)
   networks.  The architecture is given at a high-level, high level, showing the
   major components of an overall system.  An important goal is to
   divide the space into individual smaller components that can be
   implemented independently with clear inter-component interfaces and
   interactions.  It should be possible to build and implement
   individual components in isolation and have them interoperate with
   other independently implemented components.  That way, implementers
   have flexibility in implementing individual components and can
   optimize and innovate within their respective components without
   requiring changes to other components.

Status of This Memo

   This Internet-Draft document is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents not an Internet Standards Track specification; it is
   published for informational purposes.

   This document is a product of the Internet Engineering Task Force
   (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list  It represents the consensus of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Not all documents
   approved by the IESG are a maximum candidate for any level of Internet
   Standard; see Section 2 of six months RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be updated, replaced, or obsoleted by other documents obtained at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on March 24, 2017.
   http://www.rfc-editor.org/info/rfc8014.

Copyright Notice

   Copyright (c) 2016 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
   2.  Terminology . . . . . . . . . . . . . . . . . . . . . . . . .   3
   3.  Background  . . . . . . . . . . . . . . . . . . . . . . . . .   4
     3.1.  VN Service (L2 and L3)  . . . . . . . . . . . . . . . . .   6
       3.1.1.  VLAN Tags in L2 Service . . . . . . . . . . . . . . .   7
       3.1.2.  Packet Lifetime Considerations  . . . . . . . . . . .   7
     3.2.  Network Virtualization Edge (NVE) . . . . . . Background  . . . . . .   8
     3.3.  Network Virtualization Authority (NVA)  . . . . . Background . . . .   9
     3.4.  VM Orchestration Systems  . . . . . . . . . . . . . . . .  10
   4.  Network Virtualization Edge (NVE) . . . . . . . . . . . . . .  11
     4.1.  NVE Co-located With with Server Hypervisor . . . . . . . . . .  11
     4.2.  Split-NVE . . . . . . . . . . . . . . . . . . . . . . . .  12
       4.2.1.  Tenant VLAN handling Handling in Split-NVE Case  . . . . . . .  13
     4.3.  NVE State . . . . . . . . . . . . . . . . . . . . . . . .  13
     4.4.  Multi-Homing  Multihoming of NVEs . . . . . . . . . . . . . . . . . . .  14
     4.5.  Virtual Access Point (VAP)  . . . . . . . . . . . . . . .  15
   5.  Tenant System Types . . . . . . . . . . . . . . . . . . . . .  15
     5.1.  Overlay-Aware Network Service Appliances  . . . . . . . .  15
     5.2.  Bare Metal Servers  . . . . . . . . . . . . . . . . . . .  16  15
     5.3.  Gateways  . . . . . . . . . . . . . . . . . . . . . . . .  16
       5.3.1.  Gateway Taxonomy  . . . . . . . . . . . . . . . . . .  17  16
         5.3.1.1.  L2 Gateways (Bridging)  . . . . . . . . . . . . .  17
         5.3.1.2.  L3 Gateways (Only IP Packets) . . . . . . . . . .  17
     5.4.  Distributed Inter-VN Gateways . . . . . . . . . . . . . .  18
     5.5.  ARP and Neighbor Discovery  . . . . . . . . . . . . . . .  19  18
   6.  NVE-NVE Interaction . . . . . . . . . . . . . . . . . . . . .  19
   7.  Network Virtualization Authority  . . . (NVA)  . . . . . . . . . . .  20
     7.1.  How an NVA Obtains Information  . . . . . . . . . . . . .  20
     7.2.  Internal NVA Architecture . . . . . . . . . . . . . . . .  21
     7.3.  NVA External Interface  . . . . . . . . . . . . . . . . .  21
   8.  NVE-to-NVA  NVE-NVA Protocol  . . . . . . . . . . . . . . . . . . . . .  23 .  22
     8.1.  NVE-NVA Interaction Models  . . . . . . . . . . . . . . .  23
     8.2.  Direct NVE-NVA Protocol . . . . . . . . . . . . . . . . .  24  23
     8.3.  Propagating Information Between NVEs and NVAs . . . . . .  24
   9.  Federated NVAs  . . . . . . . . . . . . . . . . . . . . . . .  25
     9.1.  Inter-NVA Peering . . . . . . . . . . . . . . . . . . . .  28
   10. Control Protocol Work Areas . . . . . . . . . . . . . . . . .  28
   11. NVO3 Data Plane Data-Plane Encapsulation . . . . . . . . . . . . . . . .  28
   12. Operations, Administration Administration, and Maintenance (OAM) . . . . . .  29
   13. Summary . . . . . . . . . . . . . . . . . . . . . . . . . . .  30
   14. Acknowledgments . . . . Security Considerations . . . . . . . . . . . . . . . . . . .  30
   15. IANA Considerations . . . . . . . . . . . . . Informative References  . . . . . . . .  30
   16. Security Considerations . . . . . . . . . . . . . .  31
   Acknowledgements  . . . . .  30
   17. Informative References . . . . . . . . . . . . . . . . . . .  31  33
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  33

1.  Introduction

   This document presents a high-level architecture for building data data-
   center network virtualization overlay Network Virtualization over Layer 3 (NVO3) networks.  The
   architecture is given at a high-level, showing high level, which shows the major
   components of an overall system.  An important goal is to divide the
   space into smaller individual components that can be implemented
   independently with clear inter-component interfaces and interactions.
   It should be possible to build and implement individual components in
   isolation and have them interoperate with other independently
   implemented components.  That way, implementers have flexibility in
   implementing individual components and can optimize and innovate
   within their respective components without requiring changes to other
   components.

   The motivation for overlay networks is given in "Problem Statement:
   Overlays for Network Virtualization" [RFC7364].  "Framework for DC Data
   Center (DC) Network Virtualization" [RFC7365] provides a framework
   for discussing overlay networks generally and the various components
   that must work together in building such systems.  This document
   differs from the framework document in that it doesn't attempt to
   cover all possible approaches within the general design space.
   Rather, it describes one particular approach that the NVO3 WG has
   focused on.

2.  Terminology

   This document uses the same terminology as [RFC7365].  In addition,
   the following terms are used:

   NV Domain Domain:  A Network Virtualization Domain is an administrative
      construct that defines a Network Virtualization Authority (NVA),
      the set of Network Virtualization Edges (NVEs) associated with
      that NVA, and the set of virtual networks the NVA manages and
      supports.  NVEs are associated with a (logically centralized) NVA,
      and an NVE supports communication for any of the virtual networks
      in the domain.

   NV Region Region:  A region over which information about a set of virtual
      networks is shared.  The degenerate case of a single NV Domain
      corresponds to an NV region Region corresponding to that domain.  The
      more interesting case occurs when two or more NV Domains share
      information about part or all of a set of virtual networks that
      they manage.  Two NVAs share information about particular virtual
      networks for the purpose of supporting connectivity between
      tenants located in different NV Domains.  NVAs can share
      information about an entire NV domain, Domain, or just individual virtual
      networks.

   Tenant System Interface (TSI)  Interface (TSI):  The interface to a Virtual Network
      (VN) as presented to a Tenant System (TS, see [RFC7365]).  The TSI
      logically connects to the NVE via a Virtual Access Point (VAP).
      To the Tenant System, the TSI is like a Network Interface Card
      (NIC); the TSI presents itself to a Tenant System as a normal
      network interface.

   VLAN

   VLAN:  Unless stated otherwise, the terms VLAN "VLAN" and VLAN Tag "VLAN Tag" are
      used in this document to denote a C-VLAN [IEEE-802.1Q] and Customer VLAN (C-VLAN)
      [IEEE.802.1Q]; the terms are used interchangeably to improve
      readability.

3.  Background

   Overlay networks are an approach for providing network virtualization
   services to a set of Tenant Systems (TSs) [RFC7365].  With overlays,
   data traffic between tenants is tunneled across the underlying data
   center's IP network.  The use of tunnels provides a number of
   benefits by decoupling the network as viewed by tenants from the
   underlying physical network across which they communicate.
   Additional discussion of some NVO3 use cases can be found in
   [I-D.ietf-nvo3-use-case].
   [USECASES].

   Tenant Systems connect to Virtual Networks (VNs), with each VN having
   associated attributes defining properties of the network, such network (such as the
   set of members that connect to it. it).  Tenant Systems connected to a
   virtual network typically communicate freely with other Tenant
   Systems on the same VN, but communication between Tenant Systems on
   one VN and those external to the VN (whether on another VN or
   connected to the Internet) is carefully controlled and governed by
   policy.  The NVO3 architecture does not impose any restrictions to
   the application of policy controls even within a VN.

   A Network Virtualization Edge (NVE) [RFC7365] is the entity that
   implements the overlay functionality.  An NVE resides at the boundary
   between a Tenant System and the overlay network as shown in Figure 1.
   An NVE creates and maintains local state about each Virtual Network VN for which it
   is providing service on behalf of a Tenant System.

       +--------+                                             +--------+
       | Tenant +--+                                     +----| Tenant |
       | System |  |                                    (')   | System |
       +--------+  |          ................         (   )  +--------+
                   |  +-+--+  .              .  +--+-+  (_)
                   |  | NVE|--.              .--| NVE|   |
                   +--|    |  .              .  |    |---+
                      +-+--+  .              .   +--+-+
                      /       .              .
                     /        .  L3 Overlay  .   +--+-++--------+
       +--------+   /         .    Network   .   | NVE|| Tenant |
       | Tenant +--+          .              .- -|    || System |
       | System |             .              .   +--+-++--------+
       +--------+             ................
                                     |
                                   +----+
                                   | NVE|
                                   |    |
                                   +----+
                                     |
                                     |
                           =====================
                             |               |
                         +--------+      +--------+
                         | Tenant |      | Tenant |
                         | System |      | System |
                         +--------+      +--------+

                  Figure 1: NVO3 Generic Reference Model

   The following subsections describe key aspects of an overlay system
   in more detail.  Section 3.1 describes the service model (Ethernet
   vs. IP) provided to Tenant Systems.  Section 3.2 describes NVEs in
   more detail.  Section 3.3 introduces the Network Virtualization
   Authority, from which NVEs obtain information about virtual networks.
   Section 3.4 provides background on Virtual Machine (VM) orchestration
   systems and their use of virtual networks.

3.1.  VN Service (L2 and L3)

   A Virtual Network VN provides either L2 Layer 2 (L2) or L3 Layer 3 (L3) service to
   connected tenants.  For L2 service, VNs transport Ethernet frames,
   and a Tenant System is provided with a service that is analogous to
   being connected to a specific L2 C-VLAN.  L2 broadcast frames are
   generally delivered to all (and multicast frames delivered to a
   subset of) the other Tenant Systems on the VN.  To a Tenant System,
   it appears as if they are connected to a regular L2 Ethernet link.
   Within the NVO3 architecture, tenant frames are tunneled to remote
   NVEs based on the
   MAC Media Access Control (MAC) addresses of the frame
   headers as originated by the Tenant System.  On the underlay, NVO3
   packets are forwarded between NVEs based on the outer addresses of
   tunneled packets.

   For L3 service, VNs are routed networks that transport IP datagrams,
   and a Tenant System is provided with a service that supports only IP
   traffic.  Within the NVO3 architecture, tenant frames are tunneled to
   remote NVEs based on the IP addresses of the packet originated by the
   Tenant System; any L2 destination addresses provided by Tenant
   Systems are effectively ignored by the NVEs and overlay network.  For
   L3 service, the Tenant System will be configured with an IP subnet
   that is effectively a point-to-point link, i.e., having only the
   Tenant System and a next-hop router address on it.

   L2 service is intended for systems that need native L2 Ethernet
   service and the ability to run protocols directly over Ethernet
   (i.e., not based on IP).  L3 service is intended for systems in which
   all the traffic can safely be assumed to be IP.  It is important to
   note that whether or not an NVO3 network provides L2 or L3 service to
   a Tenant System, the Tenant System does not generally need to be
   aware of the distinction.  In both cases, the virtual network
   presents itself to the Tenant System as an L2 Ethernet interface.  An
   Ethernet interface is used in both cases simply as a widely supported
   interface type that essentially all Tenant Systems already support.
   Consequently, no special software is needed on Tenant Systems to use
   an L3 vs. an L2 overlay service.

   NVO3 can also provide a combined L2 and L3 service to tenants.  A
   combined service provides L2 service for intra-VN communication, communication but
   also provides L3 service for L3 traffic entering or leaving the VN.
   Architecturally, the handling of a combined L2/L3 service within the
   NVO3 architecture is intended to match what is commonly done today in
   non-overlay environments by devices providing a combined bridge/
   router service.  With combined service, the virtual network itself
   retains the semantics of L2 service service, and all traffic is processed
   according to its L2 semantics.  In addition, however, traffic
   requiring IP processing is also processed at the IP level.

   The IP processing for a combined service can be implemented on a
   standalone device attached to the virtual network (e.g., an IP
   router) or implemented locally on the NVE (see Section 5.4 on
   Distributed Inter-VN Gateways).  For unicast traffic, NVE
   implementation of a combined service may result in a packet being
   delivered to another Tenant System attached to the same NVE (on
   either the same or a different VN) or VN), tunneled to a remote NVE, or even
   forwarded outside the NV domain. Domain.  For multicast or broadcast packets,
   the combination of NVE L2 and L3 processing may result in copies of
   the packet receiving both L2 and L3 treatments to realize delivery to
   all of the destinations involved.  This distributed NVE
   implementation of IP routing results in the same network delivery
   behavior as if the L2 processing of the packet included delivery of
   the packet to an IP router attached to the L2 VN as a Tenant System,
   with the router having additional network attachments to other
   networks, either virtual or not.

3.1.1.  VLAN Tags in L2 Service

   An NVO3 L2 virtual network service may include encapsulated L2 VLAN
   tags provided by a Tenant System, System but does not use encapsulated tags
   in deciding where and how to forward traffic.  Such VLAN tags can be
   passed through, through so that Tenant Systems that send or expect to receive
   them can be supported as appropriate.

   The processing of VLAN tags that an NVE receives from a TS is
   controlled by settings associated with the VAP.  Just as in the case
   with ports on Ethernet switches, a number of settings are possible.
   For example, C-TAGs Customer VLAN Tags (C-TAGs) can be passed through
   transparently, they could always be stripped upon receipt from a Tenant
   System, they could be compared against a list of explicitly configured
   tags, etc.

   Note that that there are additional considerations when VLAN tags are used
   to identify both the VN and a Tenant System VLAN within that VN, as
   described in Section 4.2.1 below. 4.2.1.

3.1.2.  Packet Lifetime Considerations

   For L3 service, Tenant Systems should expect the IPv4 TTL (Time Time to
   Live) Live
   (TTL) or IPv6 Hop Limit in the packets they send to be decremented by
   at least 1.  For L2 service, neither the TTL nor the Hop Limit (when
   the packet is IP) are is modified.  The underlay network manages TTLs and
   Hop Limits in the outer IP encapsulation - -- the values in these
   fields could be independent from or related to the values in the same
   fields of tenant IP packets.

3.2.  Network Virtualization Edge (NVE) Background

   Tenant Systems connect to NVEs via a Tenant System Interface (TSI).
   The TSI logically connects to the NVE via a Virtual Access Point
   (VAP)
   (VAP), and each VAP is associated with one Virtual Network VN as shown in Figure 2.
   To the Tenant System, the TSI is like a NIC; the TSI presents itself
   to a Tenant System as a normal network interface.  On the NVE side, a
   VAP is a logical network port (virtual or physical) into a specific
   virtual network.  Note that two different Tenant Systems (and TSIs)
   attached to a common NVE can share a VAP (e.g., TS1 and TS2 in
   Figure 2) so long as they connect to the same Virtual
   Network. VN.

                    |         Data Center         Data-Center Network (IP)        |
                    |                                         |
                    +-----------------------------------------+
                         |                           |
                         |       Tunnel Overlay      |
            +------------+---------+       +---------+------------+
            | +----------+-------+ |       | +-------+----------+ |
            | |  Overlay Module  | |       | |  Overlay Module  | |
            | +---------+--------+ |       | +---------+--------+ |
            |           |          |       |           |          |
     NVE1   |           |          |       |           |          | NVE2
            |  +--------+-------+  |       |  +--------+-------+  |
            |  | VNI1      VNI2 |  |       |  | VNI1      VNI2 |  |
            |  +-+----------+---+  |       |  +-+-----------+--+  |
            |    | VAP1     | VAP2 |       |    | VAP1      | VAP2|
            +----+----------+------+       +----+-----------+-----+
                 |          |                   |           |
                 |\         |                   |           |
                 | \        |                   |          /|
          -------+--\-------+-------------------+---------/-+-------
                 |   \      |     Tenant        |        /  |
            TSI1 |TSI2\     | TSI3            TSI1  TSI2/   TSI3
                +---+ +---+ +---+             +---+ +---+   +---+
                |TS1| |TS2| |TS3|             |TS4| |TS5|   |TS6|
                +---+ +---+ +---+             +---+ +---+   +---+

                       Figure 2: NVE Reference Model

   The Overlay Module performs the actual encapsulation and
   decapsulation of tunneled packets.  The NVE maintains state about the
   virtual networks it is a part of so that it can provide the Overlay
   Module with such information such as the destination address of the NVE to
   tunnel a packet to and the Context ID that should be placed in the
   encapsulation header to identify the virtual network that a tunneled
   packet belongs to.

   On the data center network side, side facing the data-center network, the NVE sends and
   receives native IP traffic.  When ingressing traffic from a Tenant
   System, the NVE identifies the egress NVE to which the packet should
   be sent, adds an overlay encapsulation header, and sends the packet
   on the underlay network.  When receiving traffic from a remote NVE,
   an NVE strips off the encapsulation header, header and delivers the
   (original) packet to the appropriate Tenant System.  When the source
   and destination Tenant System are on the same NVE, no encapsulation
   is needed and the NVE forwards traffic directly.

   Conceptually, the NVE is a single entity implementing the NVO3
   functionality.  In practice, there are a number of different
   implementation scenarios, as described in detail in Section 4.

3.3.  Network Virtualization Authority (NVA) Background

   Address dissemination refers to the process of learning, building building,
   and distributing the mapping/forwarding information that NVEs need in
   order to tunnel traffic to each other on behalf of communicating
   Tenant Systems.  For example, in order to send traffic to a remote
   Tenant System, the sending NVE must know the destination NVE for that
   Tenant System.

   One way to build and maintain mapping tables is to use learning, as
   802.1 bridges do [IEEE-802.1Q]. [IEEE.802.1Q].  When forwarding traffic to multicast
   or unknown unicast destinations, an NVE could simply flood traffic.
   While flooding works, it can lead to traffic hot spots and can lead to
   problems in larger networks (e.g., excessive amounts of flooded
   traffic).

   Alternatively, to reduce the scope of where flooding must take place,
   or to eliminate it all together, NVEs can make use of a Network
   Virtualization Authority (NVA).  An NVA is the entity that provides
   address mapping and other information to NVEs.  NVEs interact with an
   NVA to obtain any required address mapping address-mapping information they need in
   order to properly forward traffic on behalf of tenants.  The term NVA
   "NVA" refers to the overall system, without regards regard to its scope or
   how it is implemented.  NVAs provide a service, and NVEs access that
   service via an NVE-to-NVA NVE-NVA protocol as discussed in Section 8.

   Even when an NVA is present, Ethernet bridge MAC address learning
   could be used as a fallback mechanism, should the NVA be unable to
   provide an answer or for other reasons.  This document does not
   consider flooding approaches in detail, as there are a number of
   benefits in using an approach that depends on the presence of an NVA.

   For the rest of this document, it is assumed that an NVA exists and
   will be used.  NVAs are discussed in more detail in Section 7.

3.4.  VM Orchestration Systems

   VM orchestration systems manage server virtualization across a set of
   servers.  Although VM management is a separate topic from network
   virtualization, the two areas are closely related.  Managing the
   creation, placement, and movement of VMs also involves creating,
   attaching to to, and detaching from virtual networks.  A number of
   existing VM orchestration systems have incorporated aspects of
   virtual network management into their systems.

   Note also, also that although this section uses the term terms "VM" and
   "hypervisor" throughout, the same issues apply to other
   virtualization approaches, including Linux Containers (LXC), BSD
   Jails, Network Service Appliances as discussed in Section 5.1, etc.. etc.
   From an NVO3 perspective, it should be assumed that where the
   document uses the term "VM" and "hypervisor", the intention is that
   the discussion also applies to other systems, where, e.g., the host
   operating system plays the role of the hypervisor in supporting
   virtualization, and a container plays the equivalent role as a VM.

   When a new VM image is started, the VM orchestration system
   determines where the VM should be placed, interacts with the
   hypervisor on the target server to load and start the VM VM, and
   controls when a VM should be shutdown shut down or migrated elsewhere.  VM
   orchestration systems also have knowledge about how a VM should
   connect to a network, possibly including the name of the virtual
   network to which a VM is to connect.  The VM orchestration system can
   pass such information to the hypervisor when a VM is instantiated.
   VM orchestration systems have significant (and sometimes global)
   knowledge over the domain they manage.  They typically know on what
   servers a VM is running, and meta data metadata associated with VM images can
   be useful from a network virtualization perspective.  For example,
   the meta data metadata may include the addresses (MAC and IP) the VMs will use
   and the name(s) of the virtual network(s) they connect to.

   VM orchestration systems run a protocol with an agent running on the
   hypervisor of the servers they manage.  That protocol can also carry
   information about what virtual network a VM is associated with.  When
   the orchestrator instantiates a VM on a hypervisor, the hypervisor
   interacts with the NVE in order to attach the VM to the virtual
   networks it has access to.  In general, the hypervisor will need to
   communicate significant VM state changes to the NVE.  In the reverse
   direction, the NVE may need to communicate network connectivity
   information back to the hypervisor.  Examples of deployed VM
   orchestration systems include VMware's vCenter Server, Microsoft's
   System Center Virtual Machine Manager, and systems based on OpenStack
   and its associated plugins (e.g., Nova and Neutron).  Each can pass
   information about what virtual networks a VM connects to down to the
   hypervisor.  The protocol used between the VM orchestration system
   and hypervisors is generally proprietary.

   It should be noted that VM orchestration systems may not have direct
   access to all networking related networking-related information a VM uses.  For example,
   a VM may make use of additional IP or MAC addresses that the VM
   management system is not aware of.

4.  Network Virtualization Edge (NVE)

   As introduced in Section 3.2 3.2, an NVE is the entity that implements
   the overlay functionality.  This section describes NVEs in more
   detail.  An NVE will have two external interfaces:

   Facing the Tenant System Facing: System:  On the Tenant System side facing side, the Tenant System, an
      NVE interacts with the hypervisor (or equivalent entity) to
      provide the NVO3 service.  An NVE will need to be notified when a
      Tenant System "attaches" to a virtual network (so it can validate
      the request and set up any state needed to send and receive
      traffic on behalf of the Tenant System on that VN).  Likewise, an
      NVE will need to be informed when the Tenant System "detaches"
      from the virtual network so that it can reclaim state and
      resources appropriately.

   Data Center Network Facing:

   Facing the Data-Center Network:  On the data center network side facing side, the data-center
      network, an NVE interfaces with the data center data-center underlay network,
      sending and receiving tunneled packets to and from the underlay.
      The NVE may also run a control protocol with other entities on the
      network, such as the Network Virtualization Authority.

4.1.  NVE Co-located With with Server Hypervisor

   When server virtualization is used, the entire NVE functionality will
   typically be implemented as part of the hypervisor and/or virtual
   switch on the server.  In such cases, the Tenant System interacts
   with the hypervisor hypervisor, and the hypervisor interacts with the NVE.
   Because the interaction between the hypervisor and NVE is implemented
   entirely in software on the server, there is no "on-the-wire"
   protocol between Tenant Systems (or the hypervisor) and the NVE that
   needs to be standardized.  While there may be APIs between the NVE
   and hypervisor to support necessary interaction, the details of such
   an API
   APIs are not in-scope in scope for the NVO3 WG at the time of publication of
   this memo.

   Implementing NVE functionality entirely on a server has the
   disadvantage that server CPU resources must be spent implementing the
   NVO3 functionality.  Experimentation with overlay approaches and
   previous experience with TCP and checksum adapter offloads suggests suggest
   that offloading certain NVE operations (e.g., encapsulation and
   decapsulation operations) onto the physical network adapter can
   produce performance advantages.  As has been done with checksum and/
   or TCP server offload and other optimization approaches, there may be
   benefits to offloading common operations onto adapters where
   possible.  Just as important, the addition of an overlay header can
   disable existing adapter offload capabilities that are generally not
   prepared to handle the addition of a new header or other operations
   associated with an NVE.

   While the exact details of how to split the implementation of
   specific NVE functionality between a server and its network adapters
   is
   are an implementation matter and outside the scope of IETF
   standardization, the NVO3 architecture should be cognizant of and
   support such separation.  Ideally, it may even be possible to bypass
   the hypervisor completely on critical data path data-path operations so that
   packets between a Tenant System and its VN can be sent and received
   without having the hypervisor involved in each individual packet
   operation.

4.2.  Split-NVE

   Another possible scenario leads to the need for a split NVE split-NVE
   implementation.  An NVE running on a server (e.g. (e.g., within a
   hypervisor) could support NVO3 service towards the tenant, tenant but not
   perform all NVE functions (e.g., encapsulation) directly on the
   server; some of the actual NVO3 functionality could be implemented on
   (i.e., offloaded to) an adjacent switch to which the server is
   attached.  While one could imagine a number of link types between a
   server and the NVE, one simple deployment scenario would involve a
   server and NVE separated by a simple L2 Ethernet link.  A more
   complicated scenario would have the server and NVE separated by a
   bridged access network, such as when the NVE resides on a top Top of rack Rack
   (ToR) switch, with an embedded switch residing between servers and
   the ToR switch.

   For the split NVE split-NVE case, protocols will be needed that allow the
   hypervisor and NVE to negotiate and setup set up the necessary state so
   that traffic sent across the access link between a server and the NVE
   can be associated with the correct virtual network instance.
   Specifically, on the access link, traffic belonging to a specific
   Tenant System would be tagged with a specific VLAN C-TAG that
   identifies which specific NVO3 virtual network instance it connects
   to.  The hypervisor-NVE protocol would negotiate which VLAN C-TAG to
   use for a particular virtual network instance.  More details of the
   protocol requirements for functionality between hypervisors and NVEs
   can be found in [I-D.ietf-nvo3-nve-nva-cp-req]. [NVE-NVA].

4.2.1.  Tenant VLAN handling Handling in Split-NVE Case

   Preserving tenant VLAN tags across an NVO3 VN VN, as described in
   Section 3.1.1 3.1.1, poses additional complications in the split-NVE case.
   The portion of the NVE that performs the encapsulation function needs
   access to the specific VLAN tags that the Tenant System is using in
   order to include them in the encapsulated packet.  When an NVE is
   implemented entirely within the hypervisor, the NVE has access to the
   complete original packet (including any VLAN tags) sent by the
   tenant.  In the split-NVE case, however, the VLAN tag used between
   the hypervisor and offloaded portions of the NVE normally only
   identifies the specific VN that traffic belongs to.  In order to
   allow a tenant to preserve VLAN information from end to end between
   Tenant Systems in the split-NVE case, additional mechanisms would be
   needed (e.g., carry an additional VLAN tag by carrying both a C-Tag C-TAG
   and an S-Tag a Service VLAN Tag (S-TAG) as specified in [IEEE-802.1Q] [IEEE.802.1Q] where
   the C-Tag C-TAG identifies the tenant VLAN end-to-end end to end and the S-Tag S-TAG
   identifies the VN locally between each Tenant System and the
   corresponding NVE).

4.3.  NVE State

   NVEs maintain internal data structures and state to support the
   sending and receiving of tenant traffic.  An NVE may need some or all
   of the following information:

   1.  An NVE keeps track of which attached Tenant Systems are connected
       to which virtual networks.  When a Tenant System attaches to a
       virtual network, the NVE will need to create or update the local
       state for that virtual network.  When the last Tenant System
       detaches from a given VN, the NVE can reclaim state associated
       with that VN.

   2.  For tenant unicast traffic, an NVE maintains a per-VN table of
       mappings from Tenant System (inner) addresses to remote NVE
       (outer) addresses.

   3.  For tenant multicast (or broadcast) traffic, an NVE maintains a
       per-VN table of mappings and other information on how to deliver
       tenant multicast (or broadcast) traffic.  If the underlying
       network supports IP multicast, the NVE could use IP multicast to
       deliver tenant traffic.  In such a case, the NVE would need to
       know what IP underlay multicast address to use for a given VN.
       Alternatively, if the underlying network does not support
       multicast, a source NVE could use unicast replication to deliver
       traffic.  In such a case, an NVE would need to know which remote
       NVEs are participating in the VN.  An NVE could use both
       approaches, switching from one mode to the other depending on
       such
       factors such as bandwidth efficiency and group membership
       sparseness.  [I-D.ietf-nvo3-mcast-framework]  [FRAMEWORK-MCAST] discusses the subject of multicast
       handling in NVO3 in further detail.

   4.  An NVE maintains necessary information to encapsulate outgoing
       traffic, including what type of encapsulation and what value to
       use for a Context ID to identify the VN within the encapsulation
       header.

   5.  In order to deliver incoming encapsulated packets to the correct
       Tenant Systems, an NVE maintains the necessary information to map
       incoming traffic to the appropriate VAP (i.e., Tenant System
       Interface). TSI).

   6.  An NVE may find it convenient to maintain additional per-VN
       information such as QoS settings, Path MTU information, ACLs, Access
       Control Lists (ACLs), etc.

4.4.  Multi-Homing  Multihoming of NVEs

   NVEs may be multi-homed. multihomed.  That is, an NVE may have more than one IP
   address associated with it on the underlay network.  Multihoming
   happens in two different scenarios.  First, an NVE may have multiple
   interfaces connecting it to the underlay.  Each of those interfaces
   will typically have a different IP address, resulting in a specific
   Tenant Address (on a specific VN) being reachable through the same
   NVE but through more than one underlay IP address.  Second, a
   specific tenant system Tenant System may be reachable through more than one NVE,
   each having one or more underlay addresses.  In both cases, NVE
   address mapping
   address-mapping functionality needs to support one-to-many mappings
   and enable a sending NVE to (at a minimum) be able to fail over from
   one IP address to another, e.g., should a specific NVE underlay
   address become unreachable.

   Finally, multi-homed multihomed NVEs introduce complexities when source unicast
   replication is used to implement tenant multicast as described in
   Section 4.3.  Specifically, an NVE should only receive one copy of a
   replicated packet.

   Multi-homing

   Multihoming is needed to support important use cases.  First, a bare
   metal server may have multiple uplink connections to either the same
   or different NVEs.  Having only a single physical path to an upstream
   NVE, or indeed, having all traffic flow through a single NVE would be
   considered unacceptable in highly-resilient highly resilient deployment scenarios that
   seek to avoid single points of failure.  Moreover, in today's
   networks, the availability of multiple paths would require that they
   be usable in an active-active fashion (e.g., for load balancing).

4.5.  Virtual Access Point (VAP)

   The VAP is the NVE-side NVE side of the interface between the NVE and the TS.
   Traffic to and from the tenant flows through the VAP.  If an NVE runs
   into difficulties sending traffic received on the VAP, it may need to
   signal such errors back to the VAP.  Because the VAP is an emulation
   of a physical port, its ability to signal NVE errors is limited and
   lacks sufficient granularity to reflect all possible errors an NVE
   may encounter (e.g., inability to reach a particular destination).
   Some errors, such as an NVE losing all of its connections to the
   underlay, could be reflected back to the VAP by effectively disabling
   it.  This state change would reflect itself on the TS as an interface
   going down, allowing the TS to implement interface error handling, e.g.,
   failover, handling
   (e.g., failover) in the same manner as when a physical interfaces interface
   becomes disabled.

5.  Tenant System Types

   This section describes a number of special Tenant System types and
   how they fit into an NVO3 system.

5.1.  Overlay-Aware Network Service Appliances

   Some Network Service Appliances [I-D.ietf-nvo3-nve-nva-cp-req] [NVE-NVA] (virtual or physical)
   provide tenant-aware services.  That is, the specific service they
   provide depends on the identity of the tenant making use of the
   service.  For example, firewalls are now becoming available that
   support multi-tenancy multitenancy where a single firewall provides virtual
   firewall service on a per-tenant basis, using per-tenant
   configuration rules and maintaining per-tenant state.  Such
   appliances will be aware of the VN an activity corresponds to while
   processing requests.  Unlike server virtualization, which shields VMs
   from needing to know about multi-tenancy, multitenancy, a Network Service Appliance
   may explicitly support multi-tenancy. multitenancy.  In such cases, the Network
   Service Appliance itself will be aware of network virtualization and
   either embed an NVE directly, directly or implement a split NVE split-NVE as described in
   Section 4.2.  Unlike server virtualization, however, the Network
   Service Appliance may not be running a hypervisor hypervisor, and the VM
   orchestration system may not interact with the Network Service
   Appliance.  The NVE on such appliances will need to support a control
   plane to obtain the necessary information needed to fully participate
   in an NV Domain.

5.2.  Bare Metal Servers

   Many data centers will continue to have at least some servers
   operating as non-virtualized (or "bare metal") machines running a
   traditional operating system and workload.  In such systems, there
   will be no NVE functionality on the server, and the server will have
   no knowledge of NVO3 (including whether overlays are even in use).
   In such environments, the NVE functionality can reside on the first-
   hop physical switch.  In such a case, the network administrator would
   (manually) configure the switch to enable the appropriate NVO3
   functionality on the switch port connecting the server and associate
   that port with a specific virtual network.  Such configuration would
   typically be static, since the server is not virtualized, and virtualized and, once
   configured, is unlikely to change frequently.  Consequently, this
   scenario does not require any protocol or standards work.

5.3.  Gateways

   Gateways on VNs relay traffic onto and off of a virtual network.
   Tenant Systems use gateways to reach destinations outside of the
   local VN.  Gateways receive encapsulated traffic from one VN, remove
   the encapsulation header, and send the native packet out onto the
   data center
   data-center network for delivery.  Outside traffic enters a VN in a
   reverse manner.

   Gateways can be either virtual (i.e., implemented as a VM) or
   physical (i.e., as a standalone physical device).  For performance
   reasons, standalone hardware gateways may be desirable in some cases.
   Such gateways could consist of a simple switch forwarding traffic
   from a VN onto the local data center network, data-center network or could embed router
   functionality.  On such gateways, network interfaces connecting to
   virtual networks will (at least conceptually) embed NVE (or split-
   NVE) functionality within them.  As in the case with Network Service
   Appliances, gateways may not support a hypervisor and will need an
   appropriate control plane control-plane protocol to obtain the information needed
   to provide NVO3 service.

   Gateways handle several different use cases.  For example, one use
   case consists of systems supporting overlays together with systems
   that do not (e.g., bare metal servers).  Gateways could be used to
   connect legacy systems supporting, e.g., L2 VLANs, to specific
   virtual networks, effectively making them part of the same virtual
   network.  Gateways could also forward traffic between a virtual
   network and other hosts on the data center data-center network or relay traffic
   between different VNs.  Finally, gateways can provide external
   connectivity such as Internet or VPN access.

5.3.1.  Gateway Taxonomy

   As can be seen from the discussion above, there are several types of
   gateways that can exist in an NVO3 environment.  This section breaks
   them down into the various types that could be supported.  Note that
   each of the types below could be either implemented in either a centralized
   manner or distributed to co-exist coexist with the NVEs.

5.3.1.1.  L2 Gateways (Bridging)

   L2 Gateways act as layer Layer 2 bridges to forward Ethernet frames based
   on the MAC addresses present in them.

   L2 VN to Legacy L2:  This type of gateway bridges traffic between L2
      VNs and other legacy L2 networks such as VLANs or L2 VPNs.

   L2 VN to L2 VN:  The main motivation for this type of gateway is to
      create separate groups of Tenant Systems using L2 VNs such that
      the gateway can enforce network policies between each L2 VN.

5.3.1.2.  L3 Gateways (Only IP Packets)

   L3 Gateways forward IP packets based on the IP addresses present in
   the packets.

   L3 VN to Legacy L2:  This type of gateway forwards packets between L3
      VNs and legacy L2 networks such as VLANs or L2 VPNs.  The original
      sender's destination MAC address in any frames that the gateway
      forwards from a legacy L2 network would be the MAC address of the
      gateway.

   L3 VN to Legacy L3:  The  This type of gateway forwards packets between L3
      VNs and legacy L3 networks.  These legacy L3 networks could be
      local to the data center, be in the WAN, or be an L3 VPN.

   L3 VN to L2 VN:  This type of gateway forwards packets on between L3 VNs
      and L2 VNs.  The original sender's destination MAC address in any
      frames that the gateway forwards from a L2 VN would be the MAC
      address of the gateway.

   L2 VN to L2 VN:  This type of gateway acts similar to a traditional
      router that forwards between L2 interfaces.  The original sender's
      destination MAC address in any frames that the gateway forwards
      from any of the L2 VNs would be the MAC address of the gateway.

   L3 VN to L3 VN:  The main motivation for this type of gateway is to
      create separate groups of Tenant Systems using L3 VNs such that
      the gateway can enforce network policies between each L3 VN.

5.4.  Distributed Inter-VN Gateways

   The relaying of traffic from one VN to another deserves special
   consideration.  Whether traffic is permitted to flow from one VN to
   another is a matter of policy, policy and would not (by default) be allowed
   unless explicitly enabled.  In addition, NVAs are the logical place
   to maintain policy information about allowed inter-VN communication.
   Policy enforcement for inter-VN communication can be handled in (at
   least) two different ways.  Explicit gateways could be the central
   point for such enforcement, with all inter-VN traffic forwarded to
   such gateways for processing.  Alternatively, the NVA can provide
   such information directly to NVEs, NVEs by either providing a mapping for a
   target Tenant System (TS) on another VN, VN or indicating that such
   communication is disallowed by policy.

   When inter-VN gateways are centralized, traffic between TSs on
   different VNs can take suboptimal paths, i.e., triangular routing
   results in paths that always traverse the gateway.  In the worst
   case, traffic between two TSs connected to the same NVE can be hair-
   pinned through an external gateway.  As an optimization, individual
   NVEs can be part of a distributed gateway that performs such
   relaying, reducing or completely eliminating triangular routing.  In
   a distributed gateway, each ingress NVE can perform such relaying
   activity directly, directly so long as it has access to the policy information
   needed to determine whether cross-VN communication is allowed.
   Having individual NVEs be part of a distributed gateway allows them
   to tunnel traffic directly to the destination NVE without the need to
   take suboptimal paths.

   The NVO3 architecture supports distributed gateways for the case of
   inter-VN communication.  Such support requires that NVO3 control
   protocols include mechanisms for the maintenance and distribution of
   policy information about what type of cross-VN communication is
   allowed so that NVEs acting as distributed gateways can tunnel
   traffic from one VN to another as appropriate.

   Distributed gateways could also be used to distribute other
   traditional router services to individual NVEs.  The NVO3
   architecture does not preclude such implementations, implementations but does not
   define or require them as they are outside the scope of the NVO3
   architecture.

5.5.  ARP and Neighbor Discovery

   For

   Strictly speaking, for an L2 service, strictly speaking, special processing of the
   Address Resolution Protocol (ARP) [RFC0826] (and and IPv6 Neighbor
   Discovery (ND)
   [RFC4861]) [RFC4861] is not required.  ARP requests are
   broadcast, and an NVO3 can deliver ARP requests to all members of a
   given L2 virtual
   network, network just as it does for any packet sent to an L2
   broadcast address.  Similarly, ND requests are sent via IP multicast,
   which NVO3 can support by delivering via L2 multicast.  However, as a
   performance optimization, an NVE can intercept ARP (or ND) requests
   from its attached TSs and respond to them directly using information
   in its mapping tables.  Since an NVE will have mechanisms for
   determining the NVE address associated with a given TS, the NVE can
   leverage the same mechanisms to suppress sending ARP and ND requests
   for a given TS to other members of the VN.  The NVO3 architecture
   supports such a capability.

6.  NVE-NVE Interaction

   Individual NVEs will interact with each other for the purposes of
   tunneling and delivering traffic to remote TSs.  At a minimum, a
   control protocol may be needed for tunnel setup and maintenance.  For
   example, tunneled traffic may need to be encrypted or integrity
   protected, in which case it will be necessary to set up appropriate
   security associations between NVE peers.  It may also be desirable to
   perform tunnel maintenance (e.g., continuity checks) on a tunnel in
   order to detect when a remote NVE becomes unreachable.  Such generic
   tunnel setup and maintenance functions are not generally
   NVO3-specific.  Hence, the NVO3 architecture expects to leverage
   existing tunnel maintenance protocols rather than defining new ones.

   Some NVE-NVE interactions may be specific to NVO3 (and in particular (in particular, be
   related to information kept in mapping tables) and agnostic to the
   specific tunnel type being used.  For example, when tunneling traffic
   for TS-X to a remote NVE, it is possible that TS-X is not presently
   associated with the remote NVE.  Normally, this should not happen,
   but there could be race conditions where the information an NVE has
   learned from the NVA is out-of-date out of date relative to actual conditions.
   In such cases, the remote NVE could return an error or warning
   indication, allowing the sending NVE to attempt a recovery or
   otherwise attempt to mitigate the situation.

   The NVE-NVE interaction could signal a range of indications, for
   example:

   o  "No such TS here", upon a receipt of a tunneled packet for an
      unknown TS. TS

   o  "TS-X not here, try the following NVE instead" (i.e., a redirect). redirect)

   o  Delivered  "Delivered to correct NVE, NVE but could not deliver packet to TS-X. TS-X"

   When an NVE receives information from a remote NVE that conflicts
   with the information it has in its own mapping tables, it should
   consult with the NVA to resolve those conflicts.  In particular, it
   should confirm that the information it has is up-to-date, up to date, and it
   might indicate the error to the NVA, NVA so as to nudge the NVA into
   following up (as appropriate).  While it might make sense for an NVE
   to update its mapping table temporarily in response to an error from
   a remote NVE, any changes must be handled carefully as doing so can
   raise security considerations if the received information cannot be
   authenticated.  That said, a sending NVE might still take steps to
   mitigate a problem, such as applying rate limiting to data traffic
   towards a particular NVE or TS.

7.  Network Virtualization Authority (NVA)

   Before sending traffic to and receiving traffic from a virtual
   network, an NVE must obtain the information needed to build its
   internal forwarding tables and state as listed in Section 4.3.  An
   NVE can obtain such information from a Network Virtualization Authority.

   The from a Network Virtualization
   Authority (NVA) (NVA).

   The NVA is the entity that is expected to provide address mapping and
   other information to NVEs.  NVEs can interact with an NVA to obtain
   any required information they need in order to properly forward
   traffic on behalf of tenants.  The term NVA "NVA" refers to the overall
   system, without regards regard to its scope or how it is implemented.

7.1.  How an NVA Obtains Information

   There are two primary ways in which an NVA can obtain the address
   dissemination information it manages.  The NVA can obtain information
   either manages: from the VM orchestration system,
   system and/or directly from the NVEs themselves.

   On virtualized systems, the NVA may be able to obtain the address address-
   mapping information associated with VMs from the VM orchestration
   system itself.  If the VM orchestration system contains a master
   database for all the virtualization information, having the NVA
   obtain information directly to from the orchestration system would be a
   natural approach.  Indeed, the NVA could effectively be co-located
   with the VM orchestration system itself.  In such systems, the VM
   orchestration system communicates with the NVE indirectly through the
   hypervisor.

   However, as described in Section 4 4, not all NVEs are associated with
   hypervisors.  In such cases, NVAs cannot leverage VM orchestration
   protocols to interact with an NVE and will instead need to peer
   directly with them.  By peering directly with an NVE, NVAs can obtain
   information about the TSs connected to that NVE and can distribute
   information to the NVE about the VNs those TSs are associated with.
   For example, whenever a Tenant System attaches to an NVE, that NVE
   would notify the NVA that the TS is now associated with that NVE.
   Likewise
   Likewise, when a TS detaches from an NVE, that NVE would inform the
   NVA.  By communicating directly with NVEs, both the NVA and the NVE
   are able to maintain up-to-date information about all active tenants
   and the NVEs to which they are attached.

7.2.  Internal NVA Architecture

   For reliability and fault tolerance reasons, an NVA would be
   implemented in a distributed or replicated manner without single
   points of failure.  How the NVA is implemented, however, is not
   important to an NVE so long as the NVA provides a consistent and
   well-defined interface to the NVE.  For example, an NVA could be
   implemented via database techniques whereby a server stores address address-
   mapping information in a traditional (possibly replicated) database.
   Alternatively, an NVA could be implemented in a distributed fashion
   using an existing (or modified) routing protocol to maintain and
   distribute mappings.  So long as there is a clear interface between
   the NVE and NVA, how an NVA is architected and implemented is not
   important to an NVE.

   A number of architectural approaches could be used to implement NVAs
   themselves.  NVAs manage address bindings and distribute them to
   where they need to go.  One approach would be to use the Border
   Gateway Protocol (BGP) [RFC4364] (possibly with extensions) and route
   reflectors.  Another approach could use a transaction-based database
   model with replicated servers.  Because the implementation details
   are local to an NVA, there is no need to pick exactly one solution
   technology, so long as the external interfaces to the NVEs (and
   remote NVAs) are sufficiently well defined to achieve
   interoperability.

7.3.  NVA External Interface

   Conceptually, from the perspective of an NVE, an NVA is a single
   entity.  An NVE interacts with the NVA, and it is the NVA's
   responsibility for ensuring to ensure that interactions between the NVE and NVA
   result in consistent behavior across the NVA and all other NVEs using
   the same NVA.  Because an NVA is built from multiple internal
   components, an NVA will have to ensure that information flows to all
   internal NVA components appropriately.

   One architectural question is how the NVA presents itself to the NVE.
   For example, an NVA could be required to provide access via a single
   IP address.  If NVEs only have one IP address to interact with, it
   would be the responsibility of the NVA to handle NVA component
   failures, e.g., by using a "floating IP address" that migrates among
   NVA components to ensure that the NVA can always be reached via the
   one address.  Having all NVA accesses through a single IP address,
   however, adds constraints to implementing robust failover, load
   balancing, etc.

   In the NVO3 architecture, an NVA is accessed through one or more IP
   addresses (or an IP address/port combination).  If multiple IP
   addresses are used, each IP address provides equivalent
   functionality, meaning that an NVE can use any of the provided
   addresses to interact with the NVA.  Should one address stop working,
   an NVE is expected to failover to another.  While the different
   addresses result in equivalent functionality, one address may respond
   more quickly than another, e.g., due to network conditions, load on
   the server, etc.

   To provide some control over load balancing, NVA addresses may have
   an associated priority.  Addresses are used in order of priority,
   with no explicit preference among NVA addresses having the same
   priority.  To provide basic load-balancing load balancing among NVAs of equal
   priorities, NVEs could use some randomization input to select among
   equal-priority NVAs.  Such a priority scheme facilitates failover and
   load balancing, for example, by allowing a network operator to
   specify a set of primary and backup NVAs.

   It may be desirable to have individual NVA addresses responsible for
   a subset of information about an NV Domain.  In such a case, NVEs
   would use different NVA addresses for obtaining or updating
   information about particular VNs or TS bindings.  A key question  Key questions with
   such an approach is are how information would be partitioned, partitioned and how an
   NVE could determine which address to use to get the information it
   needs.

   Another possibility is to treat the information on which NVA
   addresses to use as cached (soft-state) information at the NVEs, so
   that any NVA address can be used to obtain any information, but NVEs
   are informed of preferences for which addresses to use for particular
   information on VNs or TS bindings.  That preference information would
   be cached for future use to improve behavior - behavior, e.g., if all requests
   for a specific subset of VNs are forwarded to a specific NVA
   component, the NVE can optimize future requests within that subset by
   sending them directly to that NVA component via its address.

8.  NVE-to-NVA  NVE-NVA Protocol

   As outlined in Section 4.3, an NVE needs certain information in order
   to perform its functions.  To obtain such information from an NVA, an
   NVE-to-NVA
   NVE-NVA protocol is needed.  The NVE-to-NVA NVE-NVA protocol provides two
   functions.  First  First, it allows an NVE to obtain information about the
   location and status of other TSs with which it needs to communicate.

   Second, the NVE-to-NVA NVE-NVA protocol provides a way for NVEs to provide
   updates to the NVA about the TSs attached to that NVE (e.g., when a
   TS attaches or detaches from the NVE), NVE) or about communication errors
   encountered when sending traffic to remote NVEs.  For example, an NVE
   could indicate that a destination it is trying to reach at a
   destination NVE is unreachable for some reason.

   While having a direct NVE-to-NVA NVE-NVA protocol might seem straightforward,
   the existence of existing VM orchestration systems complicates the
   choices an NVE has for interacting with the NVA.

8.1.  NVE-NVA Interaction Models

   An NVE interacts with an NVA in at least two (quite different) ways:

   o  NVEs embedded within the same server as the hypervisor can obtain
      necessary information entirely through the hypervisor-facing side
      of the NVE.  Such an approach is a natural extension to existing
      VM orchestration systems supporting server virtualization because
      an existing protocol between the hypervisor and VM orchestration
      system already exists and can be leveraged to obtain any needed
      information.  Specifically, VM orchestration systems used to
      create, terminate terminate, and migrate VMs already use well-defined
      (though typically proprietary) protocols to handle the
      interactions between the hypervisor and VM orchestration system.
      For such systems, it is a natural extension to leverage the
      existing orchestration protocol as a sort of proxy protocol for
      handling the interactions between an NVE and the NVA.  Indeed,
      existing implementations can already do this.

   o  Alternatively, an NVE can obtain needed information by interacting
      directly with an NVA via a protocol operating over the data center data-center
      underlay network.  Such an approach is needed to support NVEs that
      are not associated with systems performing server virtualization
      (e.g., as in the case of a standalone gateway) or where the NVE
      needs to communicate directly with the NVA for other reasons.

   The NVO3 architecture will focus on support for the second model
   above.  Existing virtualization environments are already using the
   first model.  But model, but they are not sufficient to cover the case of
   standalone gateways -- such gateways may not support virtualization
   and do not interface with existing VM orchestration systems.

8.2.  Direct NVE-NVA Protocol

   An NVE can interact directly with an NVA via an NVE-to-NVA NVE-NVA protocol.
   Such a protocol can be either independent of the NVA internal
   protocol,
   protocol or an extension of it.  Using a purpose-specific protocol
   would provide architectural separation and independence between the
   NVE and NVA.  The NVE and NVA interact in a well-defined way, and
   changes in the NVA (or NVE) do not need to impact each other.  Using
   a dedicated protocol also ensures that both NVE and NVA
   implementations can evolve independently and without dependencies on
   each other.  Such independence is important because the upgrade path
   for NVEs and NVAs is quite different.  Upgrading all the NVEs at a
   site will likely be more difficult in practice than upgrading NVAs
   because of their large number - -- one on each end device.  In
   practice, it would be prudent to assume that once an NVE has been
   implemented and deployed, it may be challenging to get subsequent NVE
   extensions and changes implemented and deployed, whereas an NVA (and
   its associated internal protocols) are is more likely to evolve over time
   as experience is gained from usage and upgrades will involve fewer
   nodes.

   Requirements for a direct NVE-NVA protocol can be found in
   [I-D.ietf-nvo3-nve-nva-cp-req] [NVE-NVA].

8.3.  Propagating Information Between NVEs and NVAs

   Information flows between NVEs and NVAs in both directions.  The NVA
   maintains information about all VNs in the NV Domain, Domain so that NVEs do
   not need to do so themselves.  NVEs obtain information from the NVA information
   about where a given remote TS destination resides.  NVAs  NVAs, in turn turn,
   obtain information from NVEs about the individual TSs attached to
   those NVEs.

   While the NVA could push information relevant to every virtual
   network to every NVE, such an approach scales poorly and is
   unnecessary.  In practice, a given NVE will only need and want to
   know about VNs to which it is attached.  Thus, an NVE should be able
   to subscribe to updates only for the virtual networks it is
   interested in receiving updates for.  The NVO3 architecture supports
   a model where an NVE is not required to have full mapping tables for
   all virtual networks in an NV Domain.

   Before sending unicast traffic to a remote TS (or TSes TSs for broadcast
   or multicast traffic), an NVE must know where the remote TS(es) TS(s)
   currently reside.  When a TS attaches to a virtual network, the NVE
   obtains information about that VN from the NVA.  The NVA can provide
   that information to the NVE at the time the TS attaches to the VN,
   either because the NVE requests the information when the attach
   operation occurs, occurs or because the VM orchestration system has initiated
   the attach operation and provides associated mapping information to
   the NVE at the same time.

   There are scenarios where an NVE may wish to query the NVA about
   individual mappings within an a VN.  For example, when sending traffic
   to a remote TS on a remote NVE, that TS may become unavailable (e.g,. (e.g.,
   because it has migrated elsewhere or has been shutdown, shut down, in which
   case the remote NVE may return an error indication).  In such
   situations, the NVE may need to query the NVA to obtain updated
   mapping information for a specific TS, TS or to verify that the
   information is still correct despite the error condition.  Note that
   such a query could also be used by the NVA as an indication that
   there may be an inconsistency in the network and that it should take
   steps to verify that the information it has about the current state
   and location of a specific TS is still correct.

   For very large virtual networks, the amount of state an NVE needs to
   maintain for a given virtual network could be significant.  Moreover,
   an NVE may only be communicating with a small subset of the TSs on
   such a virtual network.  In such cases, the NVE may find it desirable
   to maintain state only for those destinations it is actively
   communicating with.  In such scenarios, an NVE may not want to
   maintain full mapping information about all destinations on a VN.
   Should
   However, if it then need needs to communicate with a destination for which it
   does not have mapping information, however, it will need to be able to query
   the NVA on demand for the missing information on a per-
   destination per-destination
   basis.

   The NVO3 architecture will need to support a range of operations
   between the NVE and NVA.  Requirements for those operations can be
   found in [I-D.ietf-nvo3-nve-nva-cp-req]. [NVE-NVA].

9.  Federated NVAs

   An NVA provides service to the set of NVEs in its NV Domain.  Each
   NVA manages network virtualization information for the virtual
   networks within its NV Domain.  An NV domain Domain is administered by a
   single entity.

   In some cases, it will be necessary to expand the scope of a specific
   VN or even an entire NV domain Domain beyond a single NVA.  For example, an
   administrator managing multiple data centers managed by the same administrator may wish to operate all
   of its data centers as a single NV region. Region.  Such cases are handled by
   having different NVAs peer with each other to exchange mapping
   information about specific VNs.  NVAs operate in a federated manner
   with a set of NVAs operating as a loosely-coupled loosely coupled federation of
   individual NVAs.  If a virtual network spans multiple NVAs (e.g.,
   located at different data centers), and an NVE needs to deliver
   tenant traffic to an NVE that is part of a different NV Domain, it
   still interacts only with its NVA, even when obtaining mappings for
   NVEs associated with a different NV Domain.

   Figure 3 shows a scenario where two separate NV Domains (1 (A and 2) B)
   share information about Virtual Network "1217". a VN.  VM1 and VM2 both connect to the same Virtual Network 1217,
   VN, even though the two VMs are in separate NV Domains.  There are
   two cases to consider.  In the first case, NV Domain B (NVB) does not allow
   NVE-A to tunnel traffic directly to NVE-B.  There could be a number
   of reasons for this.  For example, NV Domains 1 A and 2 B may not share a
   common address space (i.e., require traversal through a NAT device), device is
   required), or for policy reasons, a domain might require that all
   traffic between separate NV Domains be funneled through a particular
   device (e.g., a firewall).  In such cases, NVA-2 will advertise to
   NVA-1 that VM1 on Virtual
   Network 1217 the VN is available, available and direct that traffic between
   the two nodes go through IP-G. be forwarded via IP-G (an IP Gateway).  IP-G would then
   decapsulate received traffic from one NV Domain, translate it
   appropriately for the other domain domain, and re-encapsulate the packet for
   delivery.

                    xxxxxx                          xxxx        +-----+
   +-----+     xxxxxx    xxxxxx               xxxxxx    xxxxx   | VM2 |
   | VM1 |    xx              xx            xxx             xx  |-----|
   |-----|   xx                x          xx                 x  |NVE-B|
   |NVE-A|   x                 x  +----+  x                   x +-----+
   +--+--+   x   NV Domain A   x  |IP-G|--x                    x    |
      +-------x               xx--+    | x                     xx   |
              x              x    +----+ x     NV Domain B      x   |
           +---x           xx            xx                     x---+
           |    xxxx      xx           +->xx                   xx
           |       xxxxxxxx            |   xx                 xx
       +---+-+                         |     xx              xx
       |NVA-1|                      +--+--+    xx         xxx
       +-----+                      |NVA-2|     xxxx   xxxx
                                    +-----+        xxxxx

               Figure 3: VM1 and VM2 are in different Different NV Domains. Domains

   NVAs at one site share information and interact with NVAs at other
   sites, but only in a controlled manner.  It is expected that policy
   and access control will be applied at the boundaries between
   different sites (and NVAs) so as to minimize dependencies on external
   NVAs that could negatively impact the operation within a site.  It is
   an architectural principle that operations involving NVAs at one site
   not be immediately impacted by failures or errors at another site.
   (Of course, communication between NVEs in different NV domains Domains may be
   impacted by such failures or errors.)  It is a strong requirement
   that an NVA continue to operate properly for local NVEs even if
   external communication is interrupted (e.g., should communication
   between a local and remote NVA fail).

   At a high level, a federation of interconnected NVAs has some
   analogies to BGP and Autonomous Systems.  Like an Autonomous System,
   NVAs at one site are managed by a single administrative entity and do
   not interact with external NVAs except as allowed by policy.
   Likewise, the interface between NVAs at different sites is well
   defined,
   defined so that the internal details of operations at one site are
   largely hidden to other sites.  Finally, an NVA only peers with other
   NVAs that it has a trusted relationship with, i.e., where a VN is
   intended to span multiple NVAs.

   Reasons for using a federated model include:

   o  Provide isolation among NVAs operating at different sites at
      different geographic locations.

   o  Control the quantity and rate of information updates that flow
      (and must be processed) between different NVAs in different data
      centers.

   o  Control the set of external NVAs (and external sites) a site peers
      with.  A site will only peer with other sites that are cooperating
      in providing an overlay service.

   o  Allow policy to be applied between sites.  A site will want to
      carefully control what information it exports (and to whom) as
      well as what information it is willing to import (and from whom).

   o  Allow different protocols and architectures to be used for intra-
      NVA vs. inter-NVA communication.  For example, within a single
      data center, a replicated transaction server using database
      techniques might be an attractive implementation option for an
      NVA, and protocols optimized for intra-NVA communication would
      likely be different from protocols involving inter-NVA
      communication between different sites.

   o  Allow for optimized protocols, protocols rather than using a one-size-fits one-size-fits-
      all approach.  Within a data center, networks tend to have lower- lower
      latency, higher-speed higher speed, and higher redundancy when compared with
      WAN links interconnecting data centers.  The design constraints
      and
      tradeoffs trade-offs for a protocol operating within a data center data-center
      network are different from those operating over WAN links.  While
      a single protocol could be used for both cases, there could be
      advantages to using different and more specialized protocols for
      the intra- and inter-NVA case.

9.1.  Inter-NVA Peering

   To support peering between different NVAs, an inter-NVA protocol is
   needed.  The inter-NVA protocol defines what information is exchanged
   between NVAs.  It is assumed that the protocol will be used to share
   addressing information between data centers and must scale well over
   WAN links.

10.  Control Protocol Work Areas

   The NVO3 architecture consists of two major distinct entities: NVEs
   and NVAs.  In order to provide isolation and independence between
   these two entities, the NVO3 architecture calls for well defined well-defined
   protocols for interfacing between them.  For an individual NVA, the
   architecture calls for a logically centralized entity that could be
   implemented in a distributed or replicated fashion.  While the IETF
   may choose to define one or more specific architectural approaches to
   building individual NVAs, there is little need for it to pick exactly one
   approach to the exclusion of others.  An NVA for a single domain will
   likely be deployed as a single vendor product and thus product; thus, there is little
   benefit in standardizing the internal structure of an NVA.

   Individual NVAs peer with each other in a federated manner.  The NVO3
   architecture calls for a well-defined interface between NVAs.

   Finally, a hypervisor-to-NVE hypervisor-NVE protocol is needed to cover the split-
   NVE split-NVE
   scenario described in Section 4.2.

11.  NVO3 Data Plane Data-Plane Encapsulation

   When tunneling tenant traffic, NVEs add an encapsulation header to
   the original tenant packet.  The exact encapsulation to use for NVO3
   does not seem to be critical.  The main requirement is that the
   encapsulation support a Context ID of sufficient size.  A number of
   encapsulations already exist that provide a VN Context of sufficient
   size for NVO3.  For example, VXLAN Virtual eXtensible Local Area Network
   (VXLAN) [RFC7348] has a 24-bit VXLAN Network Identifier (VNI).  NVGRE
   Network Virtualization using Generic Routing Encapsulation (NVGRE)
   [RFC7637] has a 24-bit Tenant Network ID (TNI).  MPLS-over-GRE
   provides a 20-bit label field.  While there is widespread recognition
   that a 12-bit VN Context would be too small (only 4096 distinct
   values), it is generally agreed that 20 bits (1 million distinct
   values) and 24 bits (16.8 million distinct values) are sufficient for
   a wide variety of deployment scenarios.

12.  Operations, Administration Administration, and Maintenance (OAM)

   The simplicity of operating and debugging overlay networks will be
   critical for successful deployment.

   Overlay networks are based on tunnels between NVEs, so the OAM
   (Operations, Administration
   Operations, Administration, and Maintenance) Maintenance (OAM) [RFC6291] framework
   for overlay networks can draw from prior IETF OAM work for tunnel-based tunnel-
   based networks, specifically L2VPN OAM [RFC6136].  RFC 6136 focuses
   on Fault Management and Performance Management as fundamental to
   L2VPN service delivery, leaving the Configuration, Configuration Management,
   Accounting
   Management Management, and Security Management components of the OSI "FCAPS" Open
   Systems Interconnection (OSI) Fault, Configuration, Accounting,
   Performance, and Security (FCAPS) taxonomy [M.3400] for further
   study.  This section does likewise for NVO3 OAM, but those three
   areas continue to be important parts of complete OAM functionality
   for NVO3.

   The relationship between the overlay and underlay networks is a
   consideration for fault and performance management - -- a fault in the
   underlay may manifest as fault and/or performance issues in the
   overlay.  Diagnosing and fixing such issues are complicated by NVO3
   abstracting the underlay network away from the overlay network (e.g.,
   intermediate nodes on the underlay network path between NVEs are
   hidden from overlay VNs).

   NVO3-specific OAM techniques, protocol constructs constructs, and tools are
   needed to provide visibility beyond this abstraction to diagnose and
   correct problems that appear in the overlay.  Two examples are
   underlay-aware traceroute
   [I-D.nordmark-nvo3-transcending-traceroute], [TRACEROUTE-VXLAN] and ping protocol
   constructs for overlay networks [I-D.jain-nvo3-vxlan-ping]
   [I-D.kumar-nvo3-overlay-ping]. [VXLAN-FAILURE] [NVO3-OVERLAY].

   NVO3-specific tools and techniques are best viewed as complements to
   (i.e., not as replacements for) single-network tools that apply to
   the overlay and/or underlay networks.  Coordination among the
   individual network tools (for the overlay and underlay networks) and
   NVO3-aware
   NVO3-aware, dual-network tools is required to achieve effective
   monitoring and fault diagnosis.  For example, the defect detection
   intervals and performance measurement intervals ought to be
   coordinated among all tools involved in order to provide consistency
   and comparability of results.

   For further discussion of NVO3 OAM requirements, see
   [I-D.ashwood-nvo3-oam-requirements]. [NVO3-OAM].

13.  Summary

   This document presents the overall architecture for Network
   Virtualization Overlays (NVO3). NVO3.  The
   architecture calls for three main areas of protocol work:

   1.  A hypervisor-to-NVE hypervisor-NVE protocol to support Split NVEs split-NVEs as discussed in
       Section 4.2. 4.2

   2.  An NVE to NVA NVE-NVA protocol for disseminating VN information (e.g., inner
       to outer address mappings). mappings)

   3.  An NVA-to-NVA NVA-NVA protocol for exchange of information about specific
       virtual networks between federated NVAs. NVAs

   It should be noted that existing protocols or extensions of existing
   protocols are applicable.

15.  IANA Considerations

   This memo includes no request to IANA.

16.

14.  Security Considerations

   The data plane and control plane described in this architecture will
   need to address potential security threats.

   For the data plane, tunneled application traffic may need protection
   against being misdelivered, being modified, or having its content
   exposed to an inappropriate third party.  In all cases, encryption
   between authenticated tunnel endpoints (e.g., via use of IPsec
   [RFC4301]) and enforcing policies that control which endpoints and
   VNs are permitted to exchange traffic can be used to mitigate risks.

   For the control plane, a combination of authentication and encryption
   can be used between NVAs, between the NVA and NVE NVE, as well as between
   different components of the split-NVE approach, a combination
   of authentication and encryption can be used. approach.  All entities will
   need to properly authenticate with each other and enable encryption
   for their interactions as appropriate to protect sensitive
   information.

   Leakage of sensitive information about users or other entities
   associated with VMs whose traffic is virtualized can also be covered
   by using encryption for the control plane control-plane protocols and enforcing
   policies that control which NVO3 components are permitted to exchange
   control plane
   control-plane traffic.

   Control plane

   Control-plane elements such as NVEs and NVAs need to collect
   performance and other data in order to carry out their functions.
   This data can sometimes be unexpectedly sensitive, for example,
   allowing non-obvious inferences as to of activity within a VM.  This
   provides a reason to minimise minimize the data collected in some environments
   in order to limit potential exposure of sensitive information.  As
   noted briefly in RFC 6973 [RFC6973] and RFC 7258 [RFC7258] [RFC7258], there is
   an inevitable tension between being privacy sensitive and network
   operations that needs to be taken taking into
   account network operations in nvo3 NVO3 protocol
   development development.

   See the NVO3 framework security considerations in RFC 7365 [RFC7365]
   for further discussion.

17.

15.  Informative References

   [I-D.ietf-nvo3-mcast-framework]

   [FRAMEWORK-MCAST]
              Ghanwani, A., Dunbar, L., McBride, M., Bannai, V., and R.
              Krishnan, "A Framework for Multicast in Network
              Virtualization Overlays", draft-ietf-nvo3-mcast-
              framework-05 (work Work in progress), Progress, draft-ietf-
              nvo3-mcast-framework-05, May 2016.

   [IEEE-802.1Q]
              IEEE Std 802.1Q-2014, ,

   [IEEE.802.1Q]
              IEEE, "IEEE Standard for Local and metropolitan area networks: Bridges
              networks--Bridges and Bridged Networks",
              November 2014. IEEE 802.1Q-2014,
              DOI 10.1109/ieeestd.2014.6991462,
              <http://ieeexplore.ieee.org/servlet/
              opac?punumber=6991460>.

   [M.3400]   ITU-T Recommendation M.3400, ,   ITU-T, "TMN management functions", ITU-T
              Recommendation M.3400, February 2000.

   [I-D.ietf-nvo3-nve-nva-cp-req] 2000,
              <https://www.itu.int/rec/T-REC-M.3400-200002-I/>.

   [NVE-NVA]  Kreeger, L., Dutt, D., Narten, T., and D. Black, "Network
              Virtualization NVE to NVA Control Protocol Requirements",
              draft-ietf-nvo3-nve-nva-cp-req-05 (work
              Work in progress), Progress, draft-ietf-nvo3-nve-nva-cp-req-05, March
              2016.

   [I-D.ashwood-nvo3-oam-requirements]

   [NVO3-OAM]
              Chen, H., Ed., Ashwood-Smith, P., Xia, L., Iyengar, R.,
              Tsou, T., Sajassi, A., Boucadair, M., Jacquenet, C.,
              Daikoku, M., Ghanwani, A., and R. Krishnan, "NVO3
              Operations, Administration, and Maintenance Requirements", draft-
              ashwood-nvo3-oam-requirements-04 (work
              Work in progress), Progress, draft-ashwood-nvo3-oam-requirements-04,
              October 2015.

   [I-D.kumar-nvo3-overlay-ping]

   [NVO3-OVERLAY]
              Kumar, N., Pignataro, C., Rao, D., and S. Aldrin,
              "Detecting NVO3 Overlay Data Plane failures", draft-kumar-
              nvo3-overlay-ping-01 (work Work in progress),
              Progress, draft-kumar-nvo3-overlay-ping-01, January 2014.

   [RFC0826]  Plummer, D., "Ethernet Address Resolution Protocol: Or
              Converting Network Protocol Addresses to 48.bit Ethernet
              Address for Transmission on Ethernet Hardware", STD 37,
              RFC 826, DOI 10.17487/RFC0826, November 1982,
              <http://www.rfc-editor.org/info/rfc826>.

   [RFC4301]  Kent, S. and K. Seo, "Security Architecture for the
              Internet Protocol", RFC 4301, DOI 10.17487/RFC4301,
              December 2005, <http://www.rfc-editor.org/info/rfc4301>.

   [RFC4364]  Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
              Networks (VPNs)", RFC 4364, DOI 10.17487/RFC4364, February
              2006, <http://www.rfc-editor.org/info/rfc4364>.

   [RFC4861]  Narten, T., Nordmark, E., Simpson, W., and H. Soliman,
              "Neighbor Discovery for IP version 6 (IPv6)", RFC 4861,
              DOI 10.17487/RFC4861, September 2007,
              <http://www.rfc-editor.org/info/rfc4861>.

   [RFC6136]  Sajassi, A., Ed. and D. Mohan, Ed., "Layer 2 Virtual
              Private Network (L2VPN) Operations, Administration, and
              Maintenance (OAM) Requirements and Framework", RFC 6136,
              DOI 10.17487/RFC6136, March 2011,
              <http://www.rfc-editor.org/info/rfc6136>.

   [RFC6291]  Andersson, L., van Helvoort, H., Bonica, R., Romascanu,
              D., and S. Mansfield, "Guidelines for the Use of the "OAM"
              Acronym in the IETF", BCP 161, RFC 6291,
              DOI 10.17487/RFC6291, June 2011,
              <http://www.rfc-editor.org/info/rfc6291>.

   [RFC6973]  Cooper, A., Tschofenig, H., Aboba, B., Peterson, J.,
              Morris, J., Hansen, M., and R. Smith, "Privacy
              Considerations for Internet Protocols", RFC 6973,
              DOI 10.17487/RFC6973, July 2013,
              <http://www.rfc-editor.org/info/rfc6973>.

   [RFC7258]  Farrell, S. and H. Tschofenig, "Pervasive Monitoring Is an
              Attack", BCP 188, RFC 7258, DOI 10.17487/RFC7258, May
              2014, <http://www.rfc-editor.org/info/rfc7258>.

   [RFC7348]  Mahalingam, M., Dutt, D., Duda, K., Agarwal, P., Kreeger,
              L., Sridhar, T., Bursell, M., and C. Wright, "Virtual
              eXtensible Local Area Network (VXLAN): A Framework for
              Overlaying Virtualized Layer 2 Networks over Layer 3
              Networks", RFC 7348, DOI 10.17487/RFC7348, August 2014,
              <http://www.rfc-editor.org/info/rfc7348>.

   [RFC7364]  Narten, T., Ed., Gray, E., Ed., Black, D., Fang, L.,
              Kreeger, L., and M. Napierala, "Problem Statement:
              Overlays for Network Virtualization", RFC 7364,
              DOI 10.17487/RFC7364, October 2014,
              <http://www.rfc-editor.org/info/rfc7364>.

   [RFC7365]  Lasserre, M., Balus, F., Morin, T., Bitar, N., and Y.
              Rekhter, "Framework for Data Center (DC) Network
              Virtualization", RFC 7365, DOI 10.17487/RFC7365, October
              2014, <http://www.rfc-editor.org/info/rfc7365>.

   [RFC7637]  Garg, P., Ed. and Y. Wang, Ed., "NVGRE: Network
              Virtualization Using Generic Routing Encapsulation",
              RFC 7637, DOI 10.17487/RFC7637, September 2015,
              <http://www.rfc-editor.org/info/rfc7637>.

   [I-D.nordmark-nvo3-transcending-traceroute]

   [TRACEROUTE-VXLAN]
              Nordmark, E., Appanna, C., Lo, A., Boutros, S., and A.
              Dubey, "Layer-Transcending Traceroute for Overlay Networks
              like VXLAN", draft-nordmark-nvo3-transcending-
              traceroute-03 (work Work in progress), Progress, draft-nordmark-nvo3-
              transcending-traceroute-03, July 2016.

   [I-D.ietf-nvo3-use-case]

   [USECASES]
              Yong, L., Dunbar, L., Toy, M., Isaac, A., and V. Manral,
              "Use Cases for Data Center Network Virtualization
              Overlays", draft-ietf-nvo3-use-case-09 (work Overlay
              Networks", Work in progress),
              September Progress, draft-ietf-nvo3-use-case-12,
              October 2016.

   [I-D.jain-nvo3-vxlan-ping]

   [VXLAN-FAILURE]
              Jain, P., Singh, K., Balus, F., Henderickx, W., and V.
              Bannai, "Detecting VXLAN Segment Failure", draft-jain-
              nvo3-vxlan-ping-00 (work Work in progress),
              Progress, draft-jain-nvo3-vxlan-ping-00, June 2013.

14.  Acknowledgments

Acknowledgements

   Helpful comments and improvements to this document have come from
   Alia Atlas, Abdussalam Baryun, Spencer Dawkins, Linda Dunbar, Stephen
   Farrell, Anton Ivanov, Lizhong Jin, Suresh Krishnan, Mirja Kuehlwind,
   Greg Mirsky, Carlos Pignataro, Dennis (Xiaohong) Qin, Erik Smith,
   Takeshi Takahashi, Ziye Yang Yang, and Lucy Yong.

Authors' Addresses

   David Black
   Dell EMC

   Email: david.black@dell.com
   Jon Hudson
   Independent

   Email: jon.hudson@gmail.com

   Lawrence Kreeger
   Cisco
   Independent

   Email: kreeger@cisco.com lkreeger@gmail.com

   Marc Lasserre
   Independent

   Email: mmlasserre@gmail.com

   Thomas Narten
   IBM

   Email: narten@us.ibm.com