This is a purely informative rendering of an RFC that includes verified errata. This rendering may not be used as a reference.

The following 'Verified' errata have been incorporated in this document: EID 1655, EID 1818, EID 2791, EID 2792, EID 2814, EID 2888, EID 2889, EID 2890, EID 2891, EID 2892, EID 2903
Network Working Group                                     B. Claise, Ed.
Request for Comments: 5101                           Cisco Systems, Inc.
Category: Standards Track                                   January 2008


   Specification of the IP Flow Information Export (IPFIX) Protocol
            for the Exchange of IP Traffic Flow Information

Status of This Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Abstract

   This document specifies the IP Flow Information Export (IPFIX)
   protocol that serves for transmitting IP Traffic Flow information
   over the network.  In order to transmit IP Traffic Flow information
   from an Exporting Process to an information Collecting Process, a
   common representation of flow data and a standard means of
   communicating them is required.  This document describes how the
   IPFIX Data and Template Records are carried over a number of
   transport protocols from an IPFIX Exporting Process to an IPFIX
   Collecting Process.

Table of Contents

   1. Introduction ....................................................3
      1.1. IPFIX Documents Overview ...................................4
   2. Terminology .....................................................4
      2.1. Terminology Summary Table ..................................9
   3. IPFIX Message Format ...........................................10
      3.1. Message Header Format .....................................11
      3.2. Field Specifier Format ....................................13
      3.3. Set and Set Header Format .................................14
           3.3.1. Set Format .........................................14
           3.3.2. Set Header Format ..................................15
      3.4. Record Format .............................................16
           3.4.1. Template Record Format .............................16
           3.4.2. Options Template Record Format .....................18
                  3.4.2.1. Scope .....................................19
                  3.4.2.2. Options Template Record Format ............20
           3.4.3. Data Record Format .................................22
   4. Specific Reporting Requirements ................................23
      4.1. The Metering Process Statistics Option Template ...........23

      4.2. The Metering Process Reliability Statistics Option
           Template ..................................................24
      4.3. The Exporting Process Reliability Statistics
           Option Template ...........................................25
      4.4. The Flow Keys Option Template .............................26
   5. IPFIX Message Header "Export Time" and Flow Record Time ........27
   6. Linkage with the Information Model .............................28
      6.1. Encoding of IPFIX Data Types ..............................28
           6.1.1. Integral Data Types ................................28
           6.1.2. Address Types ......................................28
           6.1.3. float32 ............................................28
           6.1.4. float64 ............................................28
           6.1.5. boolean ............................................28
           6.1.6. string and octetarray ..............................28
           6.1.7. dateTimeSeconds ....................................29
           6.1.8. dateTimeMilliseconds ...............................29
           6.1.9. dateTimeMicroseconds ...............................29
           6.1.10.dateTimeNanoseconds.................................29
      6.2. Reduced Size Encoding of Integer and Float Types ..........29
   7. Variable-Length Information Element ............................30
   8. Template Management ............................................31
   9. The Collecting Process's Side ..................................34
   10. Transport Protocol ............................................36
      10.1. Transport Compliance and Transport Usage .................36
      10.2. SCTP .....................................................37
           10.2.1. Congestion Avoidance ..............................37
           10.2.2. Reliability .......................................37
           10.2.3. MTU ...............................................37
           10.2.4. Exporting Process .................................38
                  10.2.4.1. Association Establishment ................38
                  10.2.4.2. Association Shutdown .....................38
                  10.2.4.3. Stream ...................................38
                  10.2.4.4. Template Management ......................39
           10.2.5. Collecting Process ................................39
           10.2.6. Failover ..........................................39
      10.3. UDP ......................................................39
           10.3.1. Congestion Avoidance ..............................39
           10.3.2. Reliability .......................................40
           10.3.3. MTU ...............................................40
           10.3.4. Port Numbers ......................................40
           10.3.5. Exporting Process .................................40
           10.3.6. Template Management ...............................40
           10.3.7. Collecting Process ................................41
           10.3.8. Failover ..........................................42
      10.4. TCP ......................................................42
           10.4.1. Connection Management .............................42
                  10.4.1.1. Connection Establishment .................42
                  10.4.1.2. Graceful Connection Release ..............43

                  10.4.1.3. Restarting Interrupted Connections .......43
                  10.4.1.4. Failover .................................43
           10.4.2. Data Transmission .................................43
                  10.4.2.1. IPFIX Message Encoding ...................43
                  10.4.2.2. Template Management ......................44
                  10.4.2.3. Congestion Handling and Reliability ......44
           10.4.3. Collecting Process ................................45
   11. Security Considerations .......................................46
      11.1. Applicability of TLS and DTLS ............................47
      11.2. Usage ....................................................48
      11.3. Authentication ...........................................48
      11.4. Protection against DoS Attacks ...........................48
      11.5. When DTLS or TLS Is Not an Option ........................50
      11.6. Logging an IPFIX Attack ..................................50
      11.7. Securing the Collector ...................................51
   12. IANA Considerations ...........................................51
   Appendix A. IPFIX Encoding Examples ...............................52
      A.1. Message Header Example.....................................52
      A.2. Template Set Examples......................................53
           A.2.1. Template Set Using IETF-Specified Information
                  Elements ...........................................53
           A.2.2. Template Set Using Enterprise-Specific Information
                  Elements ...........................................53
      A.3. Data Set Example ..........................................55
      A.4. Options Template Set Examples .............................56
           A.4.1. Options Template Set Using IETF-Specified
                  Information Elements ...............................56
           A.4.2. Options Template Set Using Enterprise-Specific
                  Information Elements ...............................56
           A.4.3. Options Template Set Using an Enterprise-Specific
                  Scope ..............................................57
           A.4.4. Data Set Using an Enterprise-Specific Scope ........58
      A.5. Variable-Length Information Element Examples ..............59
           A.5.1. Example of Variable-Length Information Element
                  with Length Inferior to 255 Octets .................59
           A.5.2. Example of Variable-Length Information Element
                  with Length 255 to 65535 Octets ....................59
   References ........................................................59
      Normative References ...........................................59
      Informative References .........................................60
   Acknowledgments ...................................................61

1.  Introduction

   A data network with IP traffic primarily consists of IP flows passing
   through the network elements.  It is often interesting, useful, or
   even required to have access to information about these flows that
   pass through the network elements for administrative or other

   purposes.  The IPFIX Collecting Process should be able to receive the
   flow information passing through multiple network elements within the
   data network.  This requires uniformity in the method of representing
   the flow information and the means of communicating the flows from
   the network elements to the collection point.  This document
   specifies the protocol to achieve these aforementioned requirements.
   This document specifies in detail the representation of different
   flows, the additional data required for flow interpretation, packet
   format, transport mechanisms used, security concerns, etc.

1.1.  IPFIX Documents Overview

   The IPFIX protocol provides network administrators with access to IP
   flow information.  The architecture for the export of measured IP
   flow information out of an IPFIX Exporting Process to a Collecting
   Process is defined in [IPFIX-ARCH], per the requirements defined in
   [RFC3917].  This document specifies how IPFIX data records and
   templates are carried via a number of transport protocols from IPFIX
   Exporting Processes to IPFIX Collecting Processes.  IPFIX has a
   formal description of IPFIX Information Elements, their name, type
   and additional semantic information, as specified in [RFC5102].
   Finally, [IPFIX-AS] describes what type of applications can use the
   IPFIX protocol and how they can use the information provided.  It
   furthermore shows how the IPFIX framework relates to other
   architectures and frameworks.

2.  Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

   The definitions of the basic terms like IP Traffic Flow, Exporting
   Process, Collecting Process, Observation Points, etc.  are
   semantically identical to those found in the IPFIX requirements
   document [RFC3917].  Some of the terms have been expanded for more
   clarity when defining the protocol.  Additional terms required for
   the protocol have also been defined.  Definitions in this document
   and in [IPFIX-ARCH] are equivalent, except that definitions that are
   only relevant to the IPFIX protocol only appear here.

   The terminology summary table in Section 2.1 gives a quick overview
   of the relationships between some of the different terms defined.

   Observation Point

      An Observation Point is a location in the network where IP packets
      can be observed.  Examples include: a line to which a probe is
      attached, a shared medium, such as an Ethernet-based LAN, a single
      port of a router, or a set of interfaces (physical or logical) of
      a router.

      Note that every Observation Point is associated with an
      Observation Domain (defined below), and that one Observation Point
      may be a superset of several other Observation Points.  For
      example, one Observation Point can be an entire line card.  That
      would be the superset of the individual Observation Points at the
      line card's interfaces.

   Observation Domain

      An Observation Domain is the largest set of Observation Points for
      which Flow information can be aggregated by a Metering Process.
      For example, a router line card may be an Observation Domain if it
      is composed of several interfaces, each of which is an Observation
      Point.  In the IPFIX Message it generates, the Observation Domain
      includes its Observation Domain ID, which is unique per Exporting
      Process.  That way, the Collecting Process can identify the
      specific Observation Domain from the Exporter that sends the IPFIX
      Messages.  Every Observation Point is associated with an
      Observation Domain.  It is RECOMMENDED that Observation Domain IDs
      also be unique per IPFIX Device.

   IP Traffic Flow or Flow

      There are several definitions of the term 'flow' being used by the
      Internet community.  Within the context of IPFIX we use the
      following definition:

      A Flow is defined as a set of IP packets passing an Observation
      Point in the network during a certain time interval.  All packets
      belonging to a particular Flow have a set of common properties.
      Each property is defined as the result of applying a function to
      the values of:

         1. one or more packet header fields (e.g., destination IP
            address), transport header fields (e.g., destination port
            number), or application header fields (e.g., RTP header
            fields [RFC3550]).

         2. one or more characteristics of the packet itself (e.g.,
            number of MPLS labels, etc...).

         3. one or more of fields derived from packet treatment (e.g.,
            next hop IP address, the output interface, etc...).

      A packet is defined as belonging to a Flow if it completely
      satisfies all the defined properties of the Flow.

      This definition covers the range from a Flow containing all
      packets observed at a network interface to a Flow consisting of
      just a single packet between two applications.  It includes
      packets selected by a sampling mechanism.

   Flow Key

      Each of the fields that:

      1.  belong to the packet header (e.g., destination IP address),

      2.  are a property of the packet itself (e.g., packet length),

      3.  are derived from packet treatment (e.g., Autonomous System
          (AS) number),

      and that are used to define a Flow are termed Flow Keys.

   Flow Record

      A Flow Record contains information about a specific Flow that was
      observed at an Observation Point.  A Flow Record contains measured
      properties of the Flow (e.g., the total number of bytes for all
      the Flow's packets) and usually characteristic properties of the
      Flow (e.g., source IP address).

   Metering Process

      The Metering Process generates Flow Records.  Inputs to the
      process are packet headers and characteristics observed at an
      Observation Point, and packet treatment at the Observation Point
      (for example, the selected output interface).

      The Metering Process consists of a set of functions that includes
      packet header capturing, timestamping, sampling, classifying, and
      maintaining Flow Records.

      The maintenance of Flow Records may include creating new records,
      updating existing ones, computing Flow statistics, deriving
      further Flow properties, detecting Flow expiration, passing Flow
      Records to the Exporting Process, and deleting Flow Records.

   Exporting Process

      The Exporting Process sends Flow Records to one or more Collecting
      Processes.  The Flow Records are generated by one or more Metering
      Processes.

   Exporter

      A device that hosts one or more Exporting Processes is termed an
      Exporter.

   IPFIX Device

      An IPFIX Device hosts at least one Exporting Process.  It may host
      further Exporting Processes and arbitrary numbers of Observation
      Points and Metering Processes.

   Collecting Process

      A Collecting Process receives Flow Records from one or more
      Exporting Processes.  The Collecting Process might process or
      store received Flow Records, but such actions are out of scope for
      this document.

   Collector

      A device that hosts one or more Collecting Processes is termed a
      Collector.

   Template

      A Template is an ordered sequence of <type, length> pairs used to
      completely specify the structure and semantics of a particular set
      of information that needs to be communicated from an IPFIX Device
      to a Collector.  Each Template is uniquely identifiable by means
      of a Template ID.

   IPFIX Message

      An IPFIX Message is a message originating at the Exporting Process
      that carries the IPFIX records of this Exporting Process and whose
      destination is a Collecting Process.  An IPFIX Message is
      encapsulated at the transport layer.

   Message Header

      The Message Header is the first part of an IPFIX Message, which
      provides basic information about the message, such as the IPFIX
      version, length of the message, message sequence number, etc.

   Template Record

      A Template Record defines the structure and interpretation of
      fields in a Data Record.

   Data Record

      A Data Record is a record that contains values of the parameters
      corresponding to a Template Record.

   Options Template Record

      An Options Template Record is a Template Record that defines the
      structure and interpretation of fields in a Data Record, including
      defining how to scope the applicability of the Data Record.

   Set

      Set is a generic term for a collection of records that have a
      similar structure.  In an IPFIX Message, one or more Sets follow
      the Message Header.

      There are three different types of Sets: Template Set, Options
      Template Set, and Data Set.

   Template Set

      A Template Set is a collection of one or more Template Records
      that have been grouped together in an IPFIX Message.

   Options Template Set

      An Options Template Set is a collection of one or more Options
      Template Records that have been grouped together in an IPFIX
      Message.

   Data Set

      A Data Set is one or more Data Records, of the same type, that are
      grouped together in an IPFIX Message.  Each Data Record is
      previously defined by a Template Record or an Options Template
      Record.

   Information Element

      An Information Element is a protocol and encoding-independent
      description of an attribute that may appear in an IPFIX Record.
      The IPFIX information model [RFC5102] defines the base set of
      Information Elements for IPFIX.  The type associated with an
      Information Element indicates constraints on what it may contain
      and also determines the valid encoding mechanisms for use in
      IPFIX.

   Transport Session

      In Stream Control Transmission Protocol (SCTP), the transport
      session is known as the SCTP association, which is uniquely
      identified by the SCTP endpoints [RFC4960]; in TCP, the transport
      session is known as the TCP connection, which is uniquely
      identified by the combination of IP addresses and TCP ports used.
      In UDP, the transport session is known as the UDP session, which
      is uniquely identified by the combination of IP addresses and UDP
      ports used.

2.1.  Terminology Summary Table

   +------------------+---------------------------------------------+
   |                  |                 contents                    |
   |                  +--------------------+------------------------+
   |       Set        |      Template      |         record         |
   +------------------+--------------------+------------------------+
   |     Data Set     |          /         |     Data Record(s)     |
   +------------------+--------------------+------------------------+
   |   Template Set   | Template Record(s) |           /            |
   +------------------+--------------------+------------------------+
   | Options Template | Options Template   |           /            |
   |       Set        | Record(s)          |                        |
   +------------------+--------------------+------------------------+

   Figure A: Terminology Summary Table

   A Data Set is composed of Data Record(s).  No Template Record is
   included.  A Template Record or an Options Template Record defines
   the Data Record.

   A Template Set contains only Template Record(s).

   An Options Template Set contains only Options Template Record(s).

3.  IPFIX Message Format

   An IPFIX Message consists of a Message Header, followed by one or
   more Sets.  The Sets can be any of the possible three types: Data
   Set, Template Set, or Options Template Set.

   The format of the IPFIX Message is shown in Figure B.

   +----------------------------------------------------+
   | Message Header                                     |
   +----------------------------------------------------+
   | Set                                                |
   +----------------------------------------------------+
   | Set                                                |
   +----------------------------------------------------+
     ...
   +----------------------------------------------------+
   | Set                                                |
   +----------------------------------------------------+

   Figure B: IPFIX Message Format

   The Exporter MUST code all binary integers of the Message Header and
   the different Sets in network-byte order (also known as the
   big-endian byte ordering).

   Following are some examples of IPFIX Messages:

   1. An IPFIX Message consisting of interleaved Template, Data, and
      Options Template Sets -- A newly created Template is exported as
      soon as possible.  So, if there is already an IPFIX Message with a
      Data Set that is being prepared for export, the Template and
      Option Template Sets are interleaved with this information,
      subject to availability of space.

   +--------+--------------------------------------------------------+
   |        | +----------+ +---------+     +-----------+ +---------+ |
   |Message | | Template | | Data    |     | Options   | | Data    | |
   | Header | | Set      | | Set     | ... | Template  | | Set     | |
   |        | |          | |         |     | Set       | |         | |
   |        | +----------+ +---------+     +-----------+ +---------+ |
   +--------+--------------------------------------------------------+

   Figure C: IPFIX Message, Example 1

   2. An IPFIX Message consisting entirely of Data Sets -- After the
      appropriate Template Records have been defined and transmitted to
      the Collecting Process, the majority of IPFIX Messages consist
      solely of Data Sets.

   +--------+----------------------------------------------+
   |        | +---------+     +---------+      +---------+ |
   |Message | | Data    |     | Data    |      | Data    | |
   | Header | | Set     | ... | Set     | ...  | Set     | |
   |        | +---------+     +---------+      +---------+ |
   +--------+----------------------------------------------+

   Figure D: IPFIX Message, Example 2

   3. An IPFIX Message consisting entirely of Template and Options
      Template Sets.

   +--------+-------------------------------------------------+
   |        | +----------+     +----------+      +----------+ |
   |Message | | Template |     | Template |      | Options  | |
   | Header | | Set      | ... | Set      | ...  | Template | |
   |        | |          |     |          |      | Set      | |
   |        | +----------+     +----------+      +----------+ |
   +--------+-------------------------------------------------+

   Figure E: IPFIX Message, Example 3

3.1.  Message Header Format

   The format of the IPFIX Message Header is shown in Figure F.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |       Version Number          |            Length             |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                           Export Time                         |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                       Sequence Number                         |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Observation Domain ID                      |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure F: IPFIX Message Header Format

   Message Header Field Descriptions:

   Version

      Version of Flow Record format exported in this message.  The value
      of this field is 0x000a for the current version, incrementing by
      one the version used in the NetFlow services export version 9
      [RFC3954].

   Length

      Total length of the IPFIX Message, measured in octets, including
      Message Header and Set(s).

   Export Time

      Time, in seconds, since 0000 UTC Jan 1, 1970, at which the IPFIX
      Message Header leaves the Exporter.

   Sequence Number

      Incremental sequence counter modulo 2^32 of all IPFIX Data Records
      sent on this PR-SCTP stream from the current Observation Domain by
      the Exporting Process.  Check the specific meaning of this field
      in the subsections of Section 10 when UDP or TCP is selected as
      the transport protocol.  This value SHOULD be used by the
      Collecting Process to identify whether any IPFIX Data Records have
      been missed.  Template and Options Template Records do not
      increase the Sequence Number.

   Observation Domain ID

      A 32-bit identifier of the Observation Domain that is locally
      unique to the Exporting Process.  The Exporting Process uses the
      Observation Domain ID to uniquely identify to the Collecting
      Process the Observation Domain that metered the Flows.  It is
      RECOMMENDED that this identifier also be unique per IPFIX Device.
      Collecting Processes SHOULD use the Transport Session and the
      Observation Domain ID field to separate different export streams
      originating from the same Exporting Process.  The Observation
      Domain ID SHOULD be 0 when no specific Observation Domain ID is
      relevant for the entire IPFIX Message, for example, when exporting
      the Exporting Process Statistics, or in case of a hierarchy of
      Collectors when aggregated Data Records are exported.

3.2.  Field Specifier Format

   Vendors need the ability to define proprietary Information Elements,
   because, for example, they are delivering a pre-standards product, or
   the Information Element is, in some way, commercially sensitive.
   This section describes the Field Specifier format for both
   IETF-specified Information Elements [RFC5102] and enterprise-specific
   Information Elements.

   The Information Elements are identified by the Information Element
   identifier.  When the Enterprise bit is set to 0, the corresponding
   Information Element identifier will report an IETF-specified
   Information Element, and the Enterprise Number MUST NOT be present.
   When the Enterprise bit is set to 1, the corresponding Information
   Element identifier will report an enterprise-specific Information
   Element; the Enterprise Number MUST be present.  An example of this
   is shown in Section A.4.2.

   The Field Specifier format is shown in Figure G.

   0                   1                   2                   3
   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |E|  Information Element ident. |        Field Length           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                      Enterprise Number                        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure G: Field Specifier Format

   Where:

   E

      Enterprise bit.  This is the first bit of the Field Specifier.  If
      this bit is zero, the Information Element Identifier identifies an
      IETF-specified Information Element, and the four-octet Enterprise
      Number field MUST NOT be present.  If this bit is one, the
      Information Element identifier identifies an enterprise-specific
      Information Element, and the Enterprise Number filed MUST be
      present.

   Information Element identifier

      A numeric value that represents the type of Information Element.
      Refer to [RFC5102].

   Field Length

      The length of the corresponding encoded Information Element, in
      octets.  Refer to [RFC5102].  The field length may be smaller than
      the definition in [RFC5102] if the reduced size encoding is used
      (see Section 6.2).  The value 65535 is reserved for variable-
      length Information Elements (see Section 7).

   Enterprise Number

      IANA enterprise number [PEN] of the authority defining the
      Information Element identifier in this Template Record.

3.3.  Set and Set Header Format

   A Set is a generic term for a collection of records that have a
   similar structure.  There are three different types of Sets: Template
   Sets, Options Template Sets, and Data Sets.  Each of these Sets
   consists of a Set Header and one or more records.  The Set Format and
   the Set Header Format are defined in the following sections.

3.3.1.  Set Format

   A Set has the format shown in Figure H.  The record types can be
   either Template Records, Options Template Records, or Data Records.
   The record types MUST NOT be mixed within a Set.

   +--------------------------------------------------+
   | Set Header                                       |
   +--------------------------------------------------+
   | record                                           |
   +--------------------------------------------------+
   | record                                           |
   +--------------------------------------------------+
    ...
   +--------------------------------------------------+
   | record                                           |
   +--------------------------------------------------+
   | Padding (opt.)                                   |
   +--------------------------------------------------+

   Figure H: Set Format

   The Set Field Definitions are as follows:

   Set Header

      The Set Header Format is defined in Section 3.3.2.

   Record

      One of the record Formats: Template Record, Options Template
      Record, or Data Record Format.

   Padding

      The Exporting Process MAY insert some padding octets, so that the
      subsequent Set starts at an aligned boundary.  For security
      reasons, the padding octet(s) MUST be composed of zero (0) valued
      octets.  The padding length MUST be shorter than any allowable
      record in this Set.  If padding of the IPFIX Message is desired in
      combination with very short records, then the padding Information
      Element 'paddingOctets' [RFC5102] can be used for padding records
      such that their length is increased to a multiple of 4 or 8
      octets.  Because Template Sets are always 4-octet aligned by
      definition, padding is only needed in case of other alignments
      e.g., on 8-octet boundaries.

3.3.2.  Set Header Format

   Every Set contains a common header.  This header is defined in Figure
   I.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |          Set ID               |          Length               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure I: Set Header Format

   The Set Header Field Definitions are as follows:

   Set ID

      Set ID value identifies the Set.  A value of 2 is reserved for the
      Template Set.  A value of 3 is reserved for the Option Template
      Set.  All other values from 4 to 255 are reserved for future use.
      Values above 255 are used for Data Sets.  The Set ID values of 0
      and 1 are not used for historical reasons [RFC3954].

   Length

      Total length of the Set, in octets, including the Set Header, all
      records, and the optional padding.  Because an individual Set MAY
      contain multiple records, the Length value MUST be used to
      determine the position of the next Set.

3.4.   Record Format

   IPFIX defines three record formats, defined in the next sections: the
   Template Record Format, the Options Template Record Format, and the
   Data Record Format.

3.4.1.  Template Record Format

   One of the essential elements in the IPFIX record format is the
   Template Record.  Templates greatly enhance the flexibility of the
   record format because they allow the Collecting Process to process
   IPFIX Messages without necessarily knowing the interpretation of all
   Data Records.  A Template Record contains any combination of
   IANA-assigned and/or enterprise-specific Information Elements
   identifiers.

   The format of the Template Record is shown in Figure J.  It consists
   of a Template Record Header and one or more Field Specifiers.  The
   definition of the Field Specifiers is given in Figure G above.

   +--------------------------------------------------+
   | Template Record Header                           |
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+
    ...
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+

   Figure J: Template Record Format

   The format of the Template Record Header is shown in Figure K.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |      Template ID (> 255)      |         Field Count           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure K: Template Record Header Format

   The Template Record Header Field Definitions are as follows:

   Template ID

      Each of the newly generated Template Records is given a unique
      Template ID.  This uniqueness is local to the Transport Session
      and Observation Domain that generated the Template ID.  Template
      IDs 0-255 are reserved for Template Sets, Options Template Sets,
      and other reserved Sets yet to be created.  Template IDs of Data
      Sets are numbered from 256 to 65535.  There are no constraints
      regarding the order of the Template ID allocation.

   Field Count

      Number of fields in this Template Record.

   The example in Figure L shows a Template Set with mixed standard and
   enterprise-specific Information Elements.  It consists of a Set
   Header, a Template Header, and several Field Specifiers.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |          Set ID = 2           |          Length               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |      Template ID = 256        |         Field Count = N       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |1| Information Element id. 1.1 |        Field Length 1.1       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Enterprise Number  1.1                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |0| Information Element id. 1.2 |        Field Length 1.2       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             ...               |              ...              |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |1| Information Element id. 1.N |        Field Length 1.N       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Enterprise Number  1.N                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |      Template ID = 257        |         Field Count = M       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |0| Information Element id. 2.1 |        Field Length 2.1       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |1| Information Element id. 2.2 |        Field Length 2.2       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Enterprise Number  2.2                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             ...               |              ...              |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |1| Information Element id. 2.M |        Field Length 2.M       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Enterprise Number  2.M                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                          Padding (opt)                        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure L: Template Set Example

   Information Element Identifiers 1.2 and 2.1 are defined by the IETF
   (Enterprise bit = 0) and, therefore, do not need an Enterprise Number
   to identify them.

3.4.2.  Options Template Record Format

   Thanks to the notion of scope, The Options Template Record gives the
   Exporter the ability to provide additional information to the
   Collector that would not be possible with Flow Records alone.

   One Options Template Record example is the "Flow Keys", which reports
   the Flow Keys for a Template, which is defined as the scope.  Another
   example is the "Template configuration", which reports the
   configuration sampling parameter(s) for the Template, which is
   defined as the scope.

3.4.2.1.  Scope

   The scope, which is only available in the Options Template Set, gives
   the context of the reported Information Elements in the Data Records.
   Note that the IPFIX Message Header already contains the Observation
   Domain ID (the identifier of the Observation Domain).  If not zero,
   this Observation Domain ID can be considered as an implicit scope for
   the Data Records in the IPFIX Message.  The Observation Domain ID
   MUST be zero when the IPFIX Message contains Data Records with
   different Observation Domain ID values defined as scopes.

   Multiple Scope Fields MAY be present in the Options Template Record,
   in which case, the composite scope is the combination of the scopes.
   For example, if the two scopes are defined as "metering process" and
   "template", the combined scope is this Template for this Metering
   Process.  The order of the Scope Fields, as defined in the Options
   Template Record, is irrelevant in this case.  However, if the order
   of the Scope Fields in the Options Template Record is relevant, the
   order of the Scope Fields MUST be used.  For example, if the first
   scope defines the filtering function, while the second scope defines
   the sampling function, the order of the scope is important.  Applying
   the sampling function first, followed by the filtering function,
   would lead to potentially different Data Records than applying the
   filtering function first, followed by the sampling function.  In this
   case, the Collector deduces the function order by looking at the
   order of the scope in the Options Template Record.

   The scope is an Information Element specified in the IPFIX
   Information Model [RFC5102].  An IPFIX-compliant implementation of
   the Collecting Process SHOULD support this minimum set of Information
   Elements as scope: LineCardId, TemplateId, exporterIPv4Address,
   exporterIPv6Address, and ingressInterface.  Note that other
   Information Elements, such as meteringProcessId, exportingProcessId,
   observationDomainId, etc. are also valid scopes.  The IPFIX protocol
   doesn't prevent the use of any Information Elements for scope.
   However, some Information Element types don't make sense if specified
   as scope; for example, the counter Information Elements.

   Finally, note that the Scope Field Count MUST NOT be zero.

3.4.2.2.  Options Template Record Format

   An Options Template Record contains any combination of IANA-assigned
   and/or enterprise-specific Information Elements identifiers.

   The format of the Options Template Record is shown in Figure M.  It
   consists of an Options Template Record Header and one or more Field
   Specifiers.  The definition of the Field Specifiers is given in
   Figure G above.

   +--------------------------------------------------+
   | Options Template Record Header                   |
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+
    ...
   +--------------------------------------------------+
   | Field Specifier                                  |
   +--------------------------------------------------+

   Figure M: Options Template Record Format

   The format of the Options Template Record Header is shown in Figure
   N.

    0                  1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Template ID (> 255)   |         Field Count           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |      Scope Field Count        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure N: Options Template Record Header Format

   The Options Template Record Header Field Definitions are as follows:

   Template ID

   Template ID of this Options Template Record.  This value is greater
   than 255.

   Field Count

   Number of all fields in this Options Template Record, including the
   Scope Fields.

   Scope Field Count

   Number of scope fields in this Options Template Record.  The Scope
   Fields are normal Fields except that they are interpreted as scope at
   the Collector.  The Scope Field Count MUST NOT be zero.

   The example in Figure O shows an Option Template Set with mixed IETF
   and enterprise-specific Information Elements.  It consists of a Set
   Header, an Option Template Header, and several Field Specifiers.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |          Set ID = 3           |          Length               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Template ID = 258     |         Field Count = N + M   |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |     Scope Field Count = N     |0|  Scope 1 Infor. Element Id. |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |     Scope 1 Field Length      |0|  Scope 2 Infor. Element Id. |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |     Scope 2 Field Length      |             ...               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |            ...                |1|  Scope N Infor. Element Id. |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |     Scope N Field Length      |   Scope N Enterprise Number ...
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   ...  Scope N Enterprise Number   |1| Option 1 Infor. Element Id. |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |    Option 1 Field Length      |  Option 1 Enterprise Number ...
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   ... Option 1 Enterprise Number   |              ...              |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             ...               |0| Option M Infor. Element Id. |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |     Option M Field Length     |      Padding (optional)       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure O: Option Template Set Example

3.4.3.  Data Record Format

   The Data Records are sent in Data Sets.  The format of the Data
   Record is shown in Figure P.  It consists only of one or more Field
   Values.  The Template ID to which the Field Values belong is encoded
   in the Set Header field "Set ID", i.e., "Set ID" = "Template ID".

   +--------------------------------------------------+
   | Field Value                                      |
   +--------------------------------------------------+
   | Field Value                                      |
   +--------------------------------------------------+
    ...
   +--------------------------------------------------+
   | Field Value                                      |
   +--------------------------------------------------+

   Figure P: Data Record Format

   Note that Field Values do not necessarily have a length of 16 bits.
   Field Values are encoded according to their data type specified in
   [RFC5102].

   Interpretation of the Data Record format can be done only if the
   Template Record corresponding to the Template ID is available at the
   Collecting Process.

   The example in Figure Q shows a Data Set. It consists of a Set Header
   and several Field Values.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Set ID = Template ID        |          Length               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 1 - Field Value 1    |   Record 1 - Field Value 2    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 1 - Field Value 3    |             ...               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 2 - Field Value 1    |   Record 2 - Field Value 2    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 2 - Field Value 3    |             ...               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 3 - Field Value 1    |   Record 3 - Field Value 2    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   Record 3 - Field Value 3    |             ...               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |              ...              |      Padding (optional)       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure Q: Data Set, Containing Data Records

4.  Specific Reporting Requirements

   Some specific Options Templates and Options Template Records are
   necessary to provide extra information about the Flow Records and
   about the Metering Process.

   The Option Template and Options Template Records defined in these
   subsections, which impose some constraints on the Metering Process
   and Exporting Process implementations, MAY be implemented.  If
   implemented, the specific Option Templates SHOULD be implemented as
   specified in these subsections.

   The minimum set of Information Elements is always specified in these
   Specific IPFIX Options Templates.  Nevertheless, extra Information
   Elements may be used in these specific Options Templates.

4.1.  The Metering Process Statistics Option Template

   The Metering Process Statistics Option Template specifies the
   structure of a Data Record for reporting Metering Process statistics.
   It SHOULD contain the following Information Elements that are defined
   in [RFC5102]:

   observationDomainId
                           An identifier of an Observation Domain that
                           is locally unique to the Exporting Process.
                           This Information Element MUST be defined as a
                           Scope Field.

   exportedMessageTotalCount
                           The total number of IPFIX Messages that the
                           Exporting Process successfully sent to the
                           Collecting Process since the Exporting
                           Process re-initialization.

      exportedFlowRecordTotalCount 
                           The total number of Flow Records that the
                           Exporting Process successfully sent to the
                           Collecting Process since the Exporting
                           Process re-initialization.
EID 2814 (Verified) is as follows:

Section: 4.1

Original Text:

   exportedFlowTotalCount
                           The total number of Flow Records that the
                           Exporting Process successfully sent to the
                           Collecting Process since the Exporting
                           Process re-initialization.

Corrected Text:

   exportedFlowRecordTotalCount
                           The total number of Flow Records that the
                           Exporting Process successfully sent to the
                           Collecting Process since the Exporting
                           Process re-initialization.
Notes:
The exportedFlowRecordTotalCount Information Element (42) is incorrectly referenced in the text in this section as exportedFlowTotalCount.
exportedOctetTotalCount The total number of octets that the Exporting Process successfully sent to the Collecting Process since the Exporting Process re- initialization. The Exporting Process SHOULD export the Data Record specified by the Metering Process Statistics Option Template on a regular basis or based on some export policy. This periodicity or export policy SHOULD be configurable. Note that if several Metering Processes are available on the Exporter Observation Domain, the Information Element meteringProcessId MUST be specified as an additional Scope Field. 4.2. The Metering Process Reliability Statistics Option Template The Metering Process Reliability Option Template specifies the structure of a Data Record for reporting lack of reliability in the Metering Process. It SHOULD contain the following Information Elements that are defined in [RFC5102]: observationDomainId An identifier of an Observation Domain that is locally unique to the Exporting Process. This Information Element MUST be defined as a Scope Field. ignoredPacketTotalCount The total number of IP packets that the Metering Process did not process. ignoredOctetTotalCount The total number of octets in observed IP packets that the Metering Process did not process. time first ignored The timestamp of the first IP packet that was ignored by the Metering Process. For this timestamp, any of the "flowStart" timestamp Information Elements flowStartMilliseconds, flowStartMicroseconds, flowStartNanoseconds, and flowStartDeltaMicroseconds can be used. time last ignored The timestamp of the last IP packet that was ignored by the Metering Process. For this timestamp, any of the "flowEnd" timestamp Information Elements flowEndMilliseconds, flowEndMicroseconds, flowEndNanoseconds, and flowEndDeltaMicroseconds can be used. The Exporting Process SHOULD export the Data Record specified by the Metering Process Reliability Statistics Option Template on a regular basis or based on some export policy. This periodicity or export policy SHOULD be configurable. Note that if several Metering Processes are available on the Exporter Observation Domain, the Information Element meteringProcessId MUST be specified as an additional Scope Field. 4.3. The Exporting Process Reliability Statistics Option Template The Exporting Process Reliability Option Template specifies the structure of a Data Record for reporting lack of reliability in the Exporting process. It SHOULD contain the following Information Elements that are defined in [RFC5102]: Exporting Process ID The identifier of the Exporting Process for which lack of reliability is reported. There are three Information Elements specified in [RFC5102] that can be used for this purpose: exporterIPv4Address, exporterIPv6Address, or exportingProcessId. This Information Element MUST be defined as a Scope Field. notSentFlowTotalCount The total number of Flows that were generated by the Metering Process and dropped by the Metering Process or by the Exporting Process instead of being sent to the Collecting Process. notSentPacketTotalCount The total number of packets in Flow Records that were generated by the Metering Process and dropped by the Metering Process or by the Exporting Process instead of being sent to the Collecting Process. notSentOctetTotalCount The total number of octets in packets in Flow Records that were generated by the Metering Process and dropped by the Metering Process or by the Exporting Process instead of being sent to the Collecting Process. time first flow dropped The timestamp of the first Flow was dropped by the Metering Process. For this timestamp, any of the "flowStart" timestamp Information Elements flowStartMilliseconds, flowStartMicroseconds, flowStartNanoseconds, and flowStartDeltaMicroseconds can be used. time last flow dropped The timestamp of the last IP packet that was ignored by the Metering Process. For this timestamp, any of the "flowEnd" timestamp Information Elements flowEndMilliseconds, flowEndMicroseconds, flowEndNanoseconds, and flowEndDeltaMicroseconds can be used. The Exporting Process SHOULD export the Data Record specified by the Exporting Process Reliability Statistics Option Template on a regular basis or based on some export policy. This periodicity or export policy SHOULD be configurable. 4.4. The Flow Keys Option Template The Flow Keys Option Template specifies the structure of a Data Record for reporting the Flow Keys of reported Flows. A Flow Keys Data Record extends a particular Template Record that is referenced by its templateId identifier. The Template Record is extended by specifying which of the Information Elements contained in the corresponding Data Records describe Flow properties that serve as Flow Keys of the reported Flow. The Flow Keys Option Template SHOULD contain the following Information Elements that are defined in [RFC5102]: templateId An identifier of a Template. This Information Element MUST be defined as a Scope Field. flowKeyIndicator Bitmap with the positions of the Flow Keys in the Data Records. 5. IPFIX Message Header "Export Time" and Flow Record Time The IPFIX Message Header "Export Time" field is the time in seconds since 0000 UTC Jan 1, 1970, at which the IPFIX Message Header leaves the Exporter. The time-related Information Elements specified in [RFC5102] MAY use this "Export Time" as base time and specify an offset relative to it, instead of using a common base time, such as 0000 UTC Jan 1, 1970. All Information Elements that do not have their base time defined by their data type MUST have the base time clearly specified in their description. For example, Data Records requiring a microsecond precision can export the flow start and end times with the flowStartMicroseconds and flowEndMicroseconds Information Elements [RFC5102], containing the time since 0000 UTC Jan 1, 1970. An alternate solution is to export the flowStartDeltaMicroseconds and flowEndDeltaMicroseconds Information Elements [RFC5102] in the Data Record, which respectively report the flow start and end time offsets compared to the IPFIX Message Header "Export Time". The latter solution lowers the export bandwidth requirement while it increases the load on the Exporter, as the Exporting Process must calculate the flowStartDeltaMicroseconds and flowEndDeltaMicroseconds of every single Data Record before exporting the IPFIX Message. It must be noted that using time-related Information Elements with offset times, compared to the IPFIX Message Header "Export Time", imposes some time constraints on the Data Records contained in the IPFIX Message. In the example of flowStartDeltaMicroseconds and flowEndDeltaMicroseconds Information Elements [RFC5102], the Data Record must be exported within a maximum of 71 minutes after its creation. Otherwise, the 32-bit counter would not be sufficient to contain the flow start time offset. 6. Linkage with the Information Model The Information Elements [RFC5102] MUST be sent in canonical format in network-byte order (also known as the big-endian byte ordering). 6.1. Encoding of IPFIX Data Types The following sections will define the encoding of the data types specified in [RFC5102]. 6.1.1. Integral Data Types Integral data types -- octet, signed8, unsigned16, signed16, unsigned32, signed32, signed64, and unsigned64 -- MUST be encoded using the default canonical format in network-byte order. Signed Integral data types are represented in two's complement notation. 6.1.2. Address Types Address types -- macAddress, ipv4Address, and ipv6Address -- MUST be encoded the same way as the integral data types. The macAddress is treated as a 6-octet integer, the ipv4Address as a 4-octet integer, and the ipv6Address as a 16-octet integer. 6.1.3. float32 The float32 data type MUST be encoded as an IEEE single-precision 32-bit floating point-type, as specified in [IEEE.754.1985]. 6.1.4. float64 The float64 data type MUST be encoded as an IEEE double-precision 64-bit floating point-type, as specified in [IEEE.754.1985]. 6.1.5. boolean The boolean data type is specified according to the TruthValue in [RFC2579]: it is an integer with the value 1 for true and a value 2 for false. Every other value is undefined. The boolean data type MUST be encoded in a single octet. 6.1.6. string and octetArray The data type string represents a finite length string of valid characters of the Unicode character encoding set. The string data type MUST be encoded in UTF-8 format. The string is sent as an array of octets using an Information Element of fixed or variable length. The length of the Information Element specifies the length of the octetArray.
EID 2903 (Verified) is as follows:

Section: 6.1.6

Original Text:

6.1.6.  string and octetarray

   The data type string represents a finite length string of valid
   characters of the Unicode character encoding set.  The string data
   type MUST be encoded in UTF-8 format.  The string is sent as an array
   of octets using an Information Element of fixed or variable length.

   The length of the Information Element specifies the length of the
   octetarray.

Corrected Text:

6.1.6.  string and octetArray

   The data type string represents a finite length string of valid
   characters of the Unicode character encoding set.  The string data
   type MUST be encoded in UTF-8 format.  The string is sent as an array
   of octets using an Information Element of fixed or variable length.

   The length of the Information Element specifies the length of the
   octetArray.
Notes:
s/octetarray/octetArray/ (twice).

Also in section 6.2:
"Information Elements containing integer, string, float, and
octetarray types in the information model ..."

Per RFC5102 and IANA's IPFIX registry, the correct name is "octetArray".
6.1.7. dateTimeSeconds The data type dateTimeSeconds represents a time value in units of seconds normalized to the GMT timezone. It MUST be encoded in a 32-bit integer containing the number of seconds since 0000 UTC Jan 1, 1970. The 32-bit integer allows the time encoding up to 136 years.
EID 2888 (Verified) is as follows:

Section: 6.1.7

Original Text:

6.1.7.  dateTimeSeconds

   The data type dateTimeseconds represents a time value in units of
   seconds normalized to the GMT timezone.  It MUST be encoded in a
   32-bit integer containing the number of seconds since 0000 UTC Jan 1,
   1970.  The 32-bit integer allows the time encoding up to 136 years.

Corrected Text:

6.1.7.  dateTimeSeconds

   The data type dateTimeSeconds represents a time value in units of
   seconds normalized to the GMT timezone.  It MUST be encoded in a
   32-bit integer containing the number of seconds since 0000 UTC Jan 1,
   1970.  The 32-bit integer allows the time encoding up to 136 years.
Notes:
s/dateTimeseconds/dateTimeSeconds/

- per the section title, the definition in IANA's IPFIX registry, and usage in other IPFIX RFCs.
6.1.8. dateTimeMilliseconds The data type dateTimeMilliseconds represents a time value in units of milliseconds normalized to the GMT timezone. It MUST be encoded in a 64-bit integer containing the number of milliseconds since 0000 UTC Jan 1, 1970. 6.1.9. dateTimeMicroseconds The data type dateTimeMicroseconds represents a time value in units of microseconds normalized to the GMT timezone. It MUST be encoded in a 64-bit integer, according to the NTP format given in [RFC1305]. 6.1.10. dateTimeNanoseconds The data type of dateTimeNanoseconds represents a time value in units of nanoseconds normalized to the GMT time zone. It MUST be encoded in a 64-bit integer, according to the NTP format given in [RFC1305]. 6.2. Reduced Size Encoding of Integer and Float Types Information Elements containing integer, string, float, and octetarray types in the information model MAY be encoded using fewer octets than those implied by their type in the information model definition [RFC5102], based on the assumption that the smaller size is sufficient to carry any value the Exporter may need to deliver. This reduces the network bandwidth requirement between the Exporter and the Collector. Note that the Information Element definitions [RFC5102] will always define the maximum encoding size. For instance, the information model [RFC5102] defines byteCount as an unsigned64 type, which would require 64 bits. However, if the Exporter will never locally encounter the need to send a value larger than 4294967295, it may chose to send the value instead as an unsigned32. For example, a core router would require an unsigned64 byteCount, while an unsigned32 might be sufficient for an access router. This behavior is indicated by the Exporter by specifying a type size with a smaller length than that associated with the assigned type of the Information Element. In the example above, the Exporter would place a length of 4 versus 8 in the Template. If reduced sizing is used, it MUST only be applied to the following integer types: unsigned64, signed64, unsigned32, signed32, unsigned16, and signed16. The signed versus unsigned property of the reported value MUST be preserved. The reduction in size can be to any number of octets smaller than the original type if the data value still fits, i.e., so that only leading zeroes are dropped. For example, an unsigned64 can be reduced in size to 7, 6, 5, 4, 3, 2, or 1 octet(s). Reduced sizing can also be used to reduce float64 to float32. The float32 not only has a reduced number range, but due to the smaller mantissa, is also less precise. The reduced size encoding MUST NOT be applied to dateTimeMicroseconds or to dateTimeNanoseconds because these represent an inherent structure that would be destroyed by using less than the original number of bytes. 7. Variable-Length Information Element The IPFIX Template mechanism is optimized for fixed-length Information Elements [RFC5102]. Where an Information Element has a variable length, the following mechanism MUST be used to carry the length information for both the IETF and proprietary Information Elements. In the Template Set, the Information Element Field Length is recorded as 65535. This reserved length value notifies the Collecting Process that length of the Information Element will be carried in the Information Element content itself. In most cases, the length of the Information Element will be less than 255 octets. The following length-encoding mechanism optimizes the overhead of carrying the Information Element length in this majority case. The length is carried in the octet before the Information Element, as shown in Figure R. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Length (< 255)| Information Element | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | ... continuing as needed | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure R: Variable-Length Information Element (length < 255 octets) The length may also be encoded into 3 octets before the Information element allowing the length of the Information Element to be greater than or equal to 255 octets. In this case, first octet of the Lenght field MUST be 255, and the length is carried in the second and third octets, as shown in Figure S.
EID 2791 (Verified) is as follows:

Section: 7

Original Text:

   If the length of the Information Element is greater than or equal to
   255 octets, the length is encoded into 3 octets before the
   Information Element.  The first octet is 255, and the length is
   carried in the second and third octets, as shown in Figure S.

Corrected Text:

   The length may also be encoded into 3 octets before the Information
   element allowing the length of the Information Element to be
   greater than or equal to 255 octets. In this case, first octet of
   the Lenght field MUST be 255, and the length is carried in the 
   second and third octets, as shown in Figure S.
Notes:
The original text is ambiguous as to whether it is possible to carry a length of less than 255 encoded in a 3 octet Length field. The quoted text seems to say it is not allowed, but Figure S says that the 2nd and 3rd octets may be set to "Length (0 to 65535)".

Since there is absolutely no harm (except a little inefficiency) in using a 3 octet Length field to encode a small length, the document should be clarified to remove the ambiguity.
0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 255 | Length (0 to 65535) | IE | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | ... continuing as needed | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure S: Variable-Length Information Element (length 0 to 65535 octets) The octets carrying the length (either the first or the first three octets) MUST NOT be included in the length of the Information Element. 8. Template Management This section describes Template Management when using SCTP and PR-SCTP as the transport protocol. Any necessary changes to Template Management specifically related to TCP or UDP transport protocols are specified in Section 10. The Exporting Process assigns and maintains the Template IDs per SCTP association for the Exporter's Observation Domains. A newly created Template Record is assigned an unused Template ID by the Exporting Process. If a specific Information Element is required by a Template, but is not available in observed packets, the Exporting Process MAY choose to export Flow Records without this Information Element in a Data Record defined by a new Template. If an Information Element is required more than once in a Template, the different occurrences of this Information Element SHOULD follow the logical order of their treatments by the Metering Process. For example, if a selected packet goes through two hash functions, and if the two hash values are sent within a single Template, the first occurrence of the hash value should belong to the first hash function in the Metering Process. For example, when exporting the two source IP addresses of an IPv4 in IPv4 packets, the first sourceIPv4Address Information Element occurrence should be the IPv4 address of the outer header, while the second occurrence should be the inner header one. Template Sets and Options Template Sets may be sent on any SCTP stream. Template Sets and Options Template Sets MUST be sent reliably, using SCTP-ordered delivery. As such, the Collecting Process MUST store the Template Record information for the duration of the SCTP association so that it can interpret the corresponding Data Records that are received in subsequent Data Sets. The Exporting Process SHOULD transmit the Template Set and Options Template Set in advance of any Data Sets that use that (Options) Template ID, to help ensure that the Collector has the Template Record before receiving the first Data Record. Data Records that correspond to a Template Record MAY appear in the same and/or subsequent IPFIX Message(s). Different Observation Domains from the same SCTP association may use the same Template ID value to refer to different Templates. The Templates that are not used anymore SHOULD be deleted. Before reusing a Template ID, the Template MUST be deleted. In order to delete an allocated Template, the Template is withdrawn through the use of a Template Withdrawal Message. The Template Withdrawal Message MUST NOT be sent until sufficient time has elapsed to allow the Collecting Process to receive and process the last Data Record using this Template information. This time MUST be configurable. A suitable default value is 5 seconds after the last Data Record has been sent. The Template ID from a withdrawn Template MUST NOT be reused until sufficient time has elapsed to allow for the Collecting Process to receive and process the Template Withdrawal Message. A Template Withdrawal Message is a Template Record for that Template ID with a Field Count of 0. The format of the Template Withdrawal Message is shown in Figure T. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = (2 or 3) | Length = 16 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID N | Field Count = 0 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID ... | Field Count = 0 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID M | Field Count = 0 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure T: Template Withdrawal Message Format The Set ID field MUST contain the value 2 for Template Set Withdrawal and the value 3 for Options Template Set Withdrawal. Multiple Template IDs MAY be withdrawn with a single Template Withdrawal Message, in that case, padding MAY be used. The Template Withdrawal Message withdraws the Template IDs for the Observation Domain ID specified in the IPFIX Message Header. The Template Withdrawal Message may be sent on any SCTP stream. The Template Withdrawal Message MUST be sent reliably, using SCTP-ordered delivery. The Template Withdrawal Message MUST NOT contain new Template or Options Template Records. If the measurement parameters change such that a new Template is required, the Template MUST be withdrawn (using a Template Withdraw Message and a new Template definition) or an unused Template ID MUST be used. Examples of the measurement changes are: a new sampling rate, a new Flow expiration process, a new filtering definition, etc. When the SCTP association shuts down or the Exporting Process restarts, all Template assignments are lost and Template IDs MUST be reassigned. If the Metering Process restarts, the Exporting Process MUST either reuse the previously assigned Template ID for each Template, or it MUST withdraw the previously issued Template IDs by sending Template Withdraw Message(s) before reusing them. A Template Withdrawal Message to withdraw all Templates for the Observation Domain ID specified in the IPFIX Message Header MAY be used. Its format is shown in Figure U. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 2 | Length = 8 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID = 2 | Field Count = 0 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure U: All Data Templates Withdrawal Message Format A Template Withdrawal Message to withdraw all Options Templates for the Observation Domain ID specified in the IPFIX Message Header MAY be used. Its format is shown in Figure V. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 3 | Length = 8 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID = 3 | Field Count = 0 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure V: All Options Templates Withdrawal Message Format When the SCTP association restarts, the Exporting Process MUST resend all the Template Records. 9. The Collecting Process's Side This section describes the Collecting Process when using SCTP and PR-SCTP as the transport protocol. Any necessary changes to the Collecting Process specifically related to TCP or UDP transport protocols are specified in Section 10. The Collecting Process SHOULD listen for a new association request from the Exporting Process. The Exporting Process will request a number of streams to use for export. An Exporting Process MAY request and support more than one stream per SCTP association. If the Collecting Process receives a malformed IPFIX Message, it MUST reset the SCTP association, discard the IPFIX Message, and SHOULD log the error. Note that non-zero Set padding does not constitute a malformed IPFIX Message. Template Sets and Option Template Sets are only sent once. The Collecting Process MUST store the Template Record information for the duration of the association so that it can interpret the corresponding Data Records that are received in subsequent Data Sets. Template IDs are unique per SCTP association and per Observation Domain. If the Collecting Process receives a Template that has already been received but that has not previously been withdrawn (i.e., a Template Record from the same Exporter Observation Domain with the same Template ID received on the SCTP association), then the Collecting Process MUST shut down the association. When an SCTP association is closed, the Collecting Process MUST discard all Templates received over that association and stop decoding IPFIX Messages that use those Templates. The Collecting Process normally receives Template Records from the Exporting Process before receiving Data Records. The Data Records are then decoded and stored by the Collector. If the Template Records have not been received at the time Data Records are received, the Collecting Process MAY store the Data Records for a short period of time and decode them after the Template Records are received. A Collecting Process MUST NOT assume that the Data Set and the associated Template Set (or Options Template Set) are exported in the same IPFIX Message. The Collecting Process MUST note the Information Element identifier of any Information Element that it does not understand and MAY discard that Information Element from the Flow Record. The Collector MUST accept padding in Data Records and Template Records. The padding size is the Set Length minus the size of the Set Header (4 octets for the Set ID and the Set Length), modulo the Record size deduced from the Template Record. The IPFIX protocol has a Sequence Number field in the Export header that increases with the number of IPFIX Data Records in the IPFIX Message. A Collector may detect out-of-sequence, dropped, or duplicate IPFIX Messages by tracking the Sequence Number. A Collector SHOULD provide a logging mechanism for tracking out-of-sequence IPFIX Messages. Such out-of-sequence IPFIX Messages may be due to Exporter resource exhaustion where it cannot transmit messages at their creation rate, an Exporting Process reset, congestion on the network link between the Exporter and Collector, Collector resource exhaustion where it cannot process the IPFIX Messages at their arrival rate, out-of-order packet reception, duplicate packet reception, or an attacker injecting false messages. If a Collecting Process receives a Template Withdrawal Message, the Collecting Process MUST delete the corresponding Template Records associated with the specific SCTP association and specific Observation Domain, and stop decoding IPFIX Messages that use the withdrawn Templates. If the Collecting Process receives a Template Withdraw message for a Template Record it has not received before on this SCTP association, it MUST reset the SCTP association, discard the IPFIX Message, and SHOULD log the error as it does for malformed IPFIX Messages. A Collecting Process that receives IPFIX Messages from several Observation Domains on the same Transport Session MUST be aware that the uniqueness of the Template ID is not guaranteed across Observation Domains. The Collector MUST support the use of Templates containing multiple occurrences of the similar Information Elements. 10. Transport Protocol The IPFIX Protocol Specification has been designed to be transport protocol independent. Note that the Exporter can export to multiple Collecting Processes using independent transport protocols. The IPFIX Message Header 16-bit Length field limits the length of an IPFIX Message to 65535 octets, including the header. A Collecting Process MUST be able to handle IPFIX Message lengths of up to 65535 octets. 10.1. Transport Compliance and Transport Usage We need to differentiate between what must be implemented (so that operators can interoperably deploy compliant implementations from different vendors) and what should or could be used in various operational environments. We must also make sure that ALL implementations can operate in a congestion-aware and congestion-avoidance mode. SCTP [RFC4960] using the PR-SCTP extension specified in [RFC3758] MUST be implemented by all compliant implementations. UDP [UDP] MAY also be implemented by compliant implementations. TCP [TCP] MAY also be implemented by compliant implementations. PR-SCTP SHOULD be used in deployments where Exporters and Collectors are communicating over links that are susceptible to congestion. PR-SCTP is capable of providing any required degree of reliability. TCP MAY be used in deployments where Exporters and Collectors communicate over links that are susceptible to congestion, but PR-SCTP is preferred due to its ability to limit back pressure on Exporters and its message versus stream orientation. UDP MAY be used, although it is not a congestion-aware protocol. However, the IPFIX traffic between Exporter and Collector MUST run in an environment where IPFIX traffic has been provisioned for, or is contained through some other means. 10.2. SCTP This section describes how IPFIX can be transported over SCTP [RFC4960] using the PR-SCTP [RFC3758] extension. 10.2.1. Congestion Avoidance The SCTP transport protocol provides the required level of congestion avoidance by design. SCTP will detect congestion in the end-to-end path between the IPFIX Exporting Process and the IPFIX Collecting Process, and limit the transfer rate accordingly. When an IPFIX Exporting Process has records to export, but detects that transmission by SCTP is temporarily impossible, it can either wait until sending is possible again, or it can decide to drop the record. In the latter case, the dropped export data MUST be accounted for, so that the amount of dropped export data can be reported. 10.2.2. Reliability The SCTP transport protocol is by default reliable, but has the capability to deliver messages with partial reliability [RFC3758]. Using reliable SCTP messages for the IPFIX export is not in itself a guarantee that all Data Records will be delivered. If there is congestion on the link from the Exporting Process to the Collecting Process, or if a significant number of retransmissions are required, the send queues on the Exporting Process may fill up; the Exporting Process MAY either suspend, export, or discard the IPFIX Messages. If Data Records are discarded the IPFIX Sequence Numbers used for export MUST reflect the loss of data. 10.2.3. MTU SCTP provides the required IPFIX Message fragmentation service based on path MTU discovery. 10.2.4. Exporting Process 10.2.4.1. Association Establishment The IPFIX Exporting Process SHOULD initiate an SCTP association with the IPFIX Collecting Process. By default, the Collecting Process listens for connections on SCTP port 4739. By default, the Collecting Process listens for secure connections on SCTP port 4740 (refer to the Security Considerations section). By default, the Exporting Process tries to connect to one of these ports. It MUST be possible to configure both the Exporting and Collecting Processes to use a different SCTP port. The Exporting Process MAY establish more than one association (connection "bundle" in SCTP terminology) to the Collecting Process. An Exporting Process MAY support more than one active association to different Collecting Processes (including the case of different Collecting Processes on the same host). 10.2.4.2. Association Shutdown When an Exporting Process is shut down, it SHOULD shut down the SCTP association. When a Collecting Process no longer wants to receive IPFIX Messages, it SHOULD shut down its end of the association. The Collecting Process SHOULD continue to receive and process IPFIX Messages until the Exporting Process has closed its end of the association. When a Collecting Process detects that the SCTP association has been abnormally terminated, it MUST continue to listen for a new association establishment. When an Exporting Process detects that the SCTP association to the Collecting Process is abnormally terminated, it SHOULD try to re-establish the association. Association timeouts SHOULD be configurable. 10.2.4.3. Stream An Exporting Process MAY request more than one SCTP stream per association. Each of these streams may be used for the transmission of IPFIX Messages containing Data Sets, Template Sets, and/or Options Template Sets. Depending on the requirements of the application, the Exporting Process may send Data Sets with full or partial reliability, using ordered or out-of-order delivery, over any SCTP stream established during SCTP Association setup. An IPFIX Exporting Process MAY use any PR-SCTP Service Definition as per Section 4 of the PR-SCTP [RFC3758] specification when using partial reliability to transmit IPFIX Messages containing only Data Sets. However, Exporting Processes SHOULD mark such IPFIX Messages for retransmission for as long as resource or other constraints allow. 10.2.4.4. Template Management When the transport protocol is SCTP, the default Template Management described in Section 8 is used. 10.2.5. Collecting Process When the transport protocol is SCTP, the default Collector processing described in Section 9 is used. 10.2.6. Failover If the Collecting Process does not acknowledge the attempt by the Exporting Process to establish an association, the Exporting Process should retry using the SCTP exponential backoff feature. The Exporter MAY log an alarm if the time to establish the association exceeds a specified threshold, configurable on the Exporter. If Collecting Process failover is supported by the Exporting Process, a second SCTP association MAY be opened in advance. 10.3. UDP This section describes how IPFIX can be transported over UDP [UDP]. 10.3.1. Congestion Avoidance UDP has no integral congestion-avoidance mechanism. Its use over congestion-sensitive network paths is therefore not recommended. UDP MAY be used in deployments where Exporters and Collectors always communicate over dedicated links that are not susceptible to congestion, i.e., over provisioned links compared to the maximum export rate from the Exporters. 10.3.2. Reliability UDP is not a reliable transport protocol, and cannot guarantee delivery of messages. IPFIX Messages sent from the Exporting Process to the Collecting Process using UDP may therefore be lost. UDP MUST NOT be used unless the application can tolerate some loss of IPFIX Messages. The Collecting Process SHOULD deduce the loss and reordering of IPFIX Data Records by looking at the discontinuities in the IPFIX Sequence Number. In the case of UDP, the IPFIX Sequence Number contains the total number of IPFIX Data Records sent for the UDP Transport Session prior to the receipt of this IPFIX Message, modulo 2^32. A Collector SHOULD detect out-of-sequence, dropped, or duplicate IPFIX Messages by tracking the Sequence Number. Templates sent from the Exporting Process to the Collecting Process using UDP as a transport MUST be re-sent at regular intervals, in case previous copies were lost. 10.3.3. MTU The maximum size of exported messages MUST be configured such that the total packet size does not exceed the path MTU. If the path MTU is unknown, a maximum packet size of 512 octets SHOULD be used. 10.3.4. Port Numbers By default, the Collecting Process listens on the UDP port 4739. By default, the Collecting Process listens for secure connections on UDP port 4740 (refer to the "Security Considerations" section). By default, the Exporting Process tries to connect to one of these ports. It MUST be possible to configure both the Exporting and Collecting Processes to use a different UDP port. 10.3.5. Exporting Process The Exporting Process MAY duplicate the IPFIX Message to the several Collecting Processes. 10.3.6. Template Management When IPFIX uses UDP as the transport protocol, Template Sets and Option Template Sets MUST be re-sent at regular intervals. The frequency of the (Options) Template transmission MUST be configurable. The default value for the frequency of the (Options) Template transmission is 10 minutes. The Exporting Process SHOULD transmit the Template Set and Options Template Set in advance of any Data Sets that use that (Options) Template ID to help ensure that the Collector has the Template Record before receiving the first Data Record. In the event of configuration changes, the Exporting Process SHOULD send multiple copies of the new Template definitions, in different IPFIX Messages, at an accelerated rate. In such a case, it SHOULD transmit the changed Template Record(s) and Options Template Record(s), without any data, in advance to help ensure that the Collector will have the correct Template information before receiving the first data. If the Option Template scope is defined in another Template, then both Templates SHOULD be sent in the same IPFIX Message. For example, if a Flow Key Option Template (see Section 4.4) is sent in an Option Template, then the associated Template SHOULD be sent in the same IPFIX Message. Following a configuration change that can modify the interpretation of the Data Records (for example, a sampling rate change) a new Template ID MUST be used, and the old Template ID MUST NOT be reused until its lifetime (see Section 10.3.7) has expired. If UDP is selected as the transport protocol, the Template Withdraw Messages MUST NOT be used, as this method is inefficient due to the unreliable nature of UDP. 10.3.7. Collecting Process The Collecting Process MUST associate a lifetime with each Template (or another definition of an identifier considered unique within the Transport Session) received via UDP. Templates (and similar definitions) not refreshed by the Exporting Process within the lifetime are expired at the Collecting Process. If the Template (or other definition) is not refreshed before that lifetime has expired, the Collecting Process MUST discard that definition and any current and future associated Data Records. In which case, an alarm MUST be logged. The Collecting Process MUST NOT decode any further Data Records that are associated with the expired Template. If a Template is refreshed with a Template Record that differs from the previously received Template Record, the Collecting Process SHOULD log a warning and replace the previously received Template Record with the new one. The Template lifetime at the Collecting Process MUST be at least 3 times higher than the Template refresh timeout configured on the Exporting Process. Template IDs are unique per UDP session and per Observation Domain. At any given time, the Collecting Process SHOULD maintain the following for all the current Template Records and Options Template Records: <IPFIX Device, Exporter source UDP port, Observation Domain ID, Template ID, Template Definition, Last Received>. The Collecting Process SHOULD accept Data Records without the associated Template Record (or other definitions) required to decode the Data Record. If the Template Records (or other definitions such as Common Properties) have not been received at the time Data Records are received, the Collecting Process SHOULD store the Data Records for a short period of time and decode them after the Template Records (or other definitions) are received. The short period of time MUST be lower than the lifetime of definitions associated with identifiers considered unique within the UDP session. If the Collecting Process receives a malformed IPFIX Message, it MUST discard the IPFIX Message and SHOULD log the error. 10.3.8. Failover Because UDP is not a connection-oriented protocol, the Exporting Process is unable to determine from the transport protocol that the Collecting Process is no longer able to receive the IPFIX Messages. Therefore, it cannot invoke a failover mechanism. However, the Exporting Process MAY duplicate the IPFIX Message to several Collecting Processes. 10.4. TCP This section describes how IPFIX can be transported over TCP [TCP]. 10.4.1. Connection Management 10.4.1.1. Connection Establishment The IPFIX Exporting Process initiates a TCP connection to the Collecting Process. By default, the Collecting Process listens for connections on TCP port 4739. By default, the Collecting Process listens for secure connections on TCP port 4740 (refer to the Security Considerations section). By default, the Exporting Process tries to connect to one of these ports. It MUST be possible to configure both the Exporting Process and the Collecting Process to use a different TCP port. An Exporting Process MAY support more than one active connection to different Collecting Processes (including the case of different Collecting Processes on the same host). The Exporter MAY log an alarm if the time to establish the connection exceeds a specified threshold, configurable on the Exporter. 10.4.1.2. Graceful Connection Release When an Exporting Process is shut down, it SHOULD shut down the TCP connection. When a Collecting Process no longer wants to receive IPFIX Messages, it SHOULD close its end of the connection. The Collecting Process SHOULD continue to read IPFIX Messages until the Exporting Process has closed its end. 10.4.1.3. Restarting Interrupted Connections When a Collecting Process detects that the TCP connection to the Exporting Process has terminated abnormally, it MUST continue to listen for a new connection. When an Exporting Process detects that the TCP connection to the Collecting Process has terminated abnormally, it SHOULD try to re-establish the connection. Connection timeouts and retry schedules SHOULD be configurable. In the default configuration, an Exporting Process MUST NOT attempt to establish a connection more frequently than once per minute. 10.4.1.4. Failover If the Collecting Process does not acknowledge the attempt by the Exporting Process to establish a connection, it will retry using the TCP exponential backoff feature. If Collecting Process failover is supported by the Exporting Process, a second TCP connection MAY be opened in advance. 10.4.2. Data Transmission Once a TCP connection is established, the Exporting Process starts sending IPFIX Messages to the Collecting Process. 10.4.2.1. IPFIX Message Encoding IPFIX Messages are sent over the TCP connection without any special encoding. The Length field in the IPFIX Message Header defines the end of each IPFIX Message and thus the start of the next IPFIX Message. This means that IPFIX Messages cannot be interleaved. In the case of TCP, the IPFIX Sequence Number contains the total number of IPFIX Data Records sent from this TCP connection, from the current Observation Domain by the Exporting Process, prior to the receipt of this IPFIX Message, modulo 2^32. If an Exporting Process exports data from multiple Observation Domains, it should be careful to choose IPFIX Message lengths appropriately to minimize head-of-line blocking between different Observation Domains. Multiple TCP connections MAY be used to avoid head-of-line between different Observation Domains. 10.4.2.2. Template Management For each Template, the Exporting Process MUST send the Template Record before exporting Data Records that refer to that Template. Template IDs are unique per TCP connection and per Observation Domain. A Collecting Process MUST record all Template and Options Template Records for the duration of the connection, as an Exporting Process is not required to re-export Template Records. When the TCP connection restarts, the Exporting Process MUST resend all the Template Records. When a TCP connection is closed, the Collecting Process MUST discard all Templates received over that connection and stop decoding IPFIX Messages that use those Templates. The Templates that are not used anymore SHOULD be deleted. Before reusing a Template ID, the Template MUST be deleted. In order to delete an allocated Template, the Template is withdrawn through the use of a Template Withdrawal Message over the TCP connection. If the Collecting Process receives a malformed IPFIX Message, it MUST reset the TCP connection, discard the IPFIX Message, and SHOULD log the error. 10.4.2.3. Congestion Handling and Reliability TCP ensures reliable delivery of data from the Exporting Process to the Collecting Process. TCP also controls the rate at which data can be sent from the Exporting Process to the Collecting Process, using a mechanism that takes into account both congestion in the network and the capabilities of the receiver. Therefore, an IPFIX Exporting Process may not be able to send IPFIX Messages at the rate that the Metering Process generates it, either because of congestion in the network or because the Collecting Process cannot handle IPFIX Messages fast enough. As long as congestion is transient, the Exporting Process can buffer IPFIX Messages for transmission. But such buffering is necessarily limited, both because of resource limitations and because of timeliness requirements, so ongoing and/or severe congestion may lead to a situation where the Exporting Process is blocked. When an Exporting Process has Data Records to export but the transmission buffer is full, and it wants to avoid blocking, it can decide to drop some Data Records. The dropped Data Records MUST be accounted for, so that the amount can later be exported. When an Exporting Process finds that the rate at which records should be exported is consistently higher than the rate at which TCP sending permits, it should provide back pressure to the Metering Processes. The Metering Process could then adapt by temporarily reducing the amount of data it generates, for example, using sampling or aggregation. 10.4.3. Collecting Process The Collecting Process SHOULD listen for a new TCP connection from the Exporting Process. If the Collecting Process receives a malformed IPFIX Message, it MUST reset the TCP connection, discard the IPFIX Message, and SHOULD log the error. Note that non-zero Set padding does not constitute a malformed IPFIX Message. Template Sets and Option Template Sets are only sent once. The Collecting Process MUST store the Template Record information for the duration of the connection so that it can interpret the corresponding Data Records that are received in subsequent Data Sets. Template IDs are unique per TCP connection and per Observation Domain. If the Collecting Process receives a Template that has already been received but that has not previously been withdrawn (i.e., a Template Record from the same Exporter Observation Domain with the same Template ID received on the TCP connection), then the Collecting Process MUST shut down the connection. When a TCP connection is closed, the Collecting Process MUST discard all Templates received over that connection and stop decoding IPFIX Messages that use those Templates. If a Collecting Process receives a Template Withdrawal Message, the Collecting Process MUST delete the corresponding Template Records associated with the specific TCP connection and specific Observation Domain, and stop decoding IPFIX Messages that use the withdrawn Templates. If the Collecting Process receives a Template Withdrawal Message for a Template Record it has not received before on this TCP connection, it MUST reset the TCP association, discard the IPFIX Message, and SHOULD log the error as it does for malformed IPFIX Messages. 11. Security Considerations The security considerations for the IPFIX protocol have been derived from an analysis of potential security threats, as discussed in the "Security Considerations" section of IPFIX requirements [RFC3917]. The requirements for IPFIX security are as follows: 1. IPFIX must provide a mechanism to ensure the confidentiality of IPFIX data transferred from an Exporting Process to a Collecting Process, in order to prevent disclosure of Flow Records transported via IPFIX. 2. IPFIX must provide a mechanism to ensure the integrity of IPFIX data transferred from an Exporting Process to a Collecting Process, in order to prevent the injection of incorrect data or control information (e.g., Templates) into an IPFIX Message stream. 3. IPFIX must provide a mechanism to authenticate IPFIX Collecting and Exporting Processes, to prevent the collection of data from an unauthorized Exporting Process or the export of data to an unauthorized Collecting Process. Because IPFIX can be used to collect information for network forensics and billing purposes, attacks designed to confuse, disable, or take information from an IPFIX collection system may be seen as a prime objective during a sophisticated network attack. An attacker in a position to inject false messages into an IPFIX Message stream can either affect the application using IPFIX (by falsifying data), or the IPFIX Collecting Process itself (by modifying or revoking Templates, or changing options); for this reason, IPFIX Message integrity is important. The IPFIX Messages themselves may also contain information of value to an attacker, including information about the configuration of the network as well as end-user traffic and payload data, so care must be taken to confine their visibility to authorized users. When an Information Element containing end-user payload information is exported, it SHOULD be transmitted to the Collecting Process using a means that secures its contents against eavesdropping. Suitable mechanisms include the use of either a direct point-to-point connection or the use of an encryption mechanism. It is the responsibility of the Collecting Process to provide a satisfactory degree of security for this collected data, including, if necessary, anonymization of any reported data. 11.1. Applicability of TLS and DTLS Transport Layer Security (TLS) [RFC4346] and Datagram Transport Layer Security (DTLS) [RFC4347] were designed to provide the confidentiality, integrity, and authentication assurances required by the IPFIX protocol, without the need for pre-shared keys. With the mandatory SCTP and PR-SCTP transport protocols for IPFIX, DTLS [RFC4347] MUST be implemented. If UDP is selected as the IPFIX transport protocol, DTLS [RFC4347] MUST be implemented. If TCP is selected as the IPFIX transport protocol, TLS [RFC4346] MUST be implemented. Note that DTLS is selected as the security mechanism for SCTP and PR-SCTP. Though TLS bindings to SCTP are defined in [RFC3436], they require all communication to be over reliable, bidirectional streams, and require one TLS connection per stream. This arrangement is not compatible with the rationale behind the choice of SCTP as an IPFIX transport protocol. Note that using DTLS [RFC4347] has a vulnerability, i.e., a true man in the middle may attempt to take data out of an association and fool the sender into thinking that the data was actually received by the peer. In generic TLS for SCTP (and/or TCP), this is not possible. This means that the removal of a message may become hidden from the sender or receiver. Another vulnerability of using PR-SCTP with DTLS is that someone could inject SCTP control information to shut down the SCTP association, effectively generating a loss of IPFIX Messages if those are buffered outside of the SCTP association. In the future, techniques such as [dtls-for-sctp] could be used to overcome these vulnerabilities. When using DTLS over SCTP, the Exporting Process MUST ensure that each IPFIX Message is sent over the same SCTP stream that would be used when sending the same IPFIX Message directly over SCTP. Note that DTLS may send its own control messages on stream 0 with full reliability; however, this will not interfere with the processing of stream 0 IPFIX Messages at the Collecting Process, because DTLS consumes its own control messages before passing IPFIX Messages up to the application layer. 11.2. Usage The IPFIX Exporting Process initiates the communication to the IPFIX Collecting Process, and acts as a TLS or DTLS client according to [RFC4346] and [RFC4347], while the IPFIX Collecting Process acts as a TLS or DTLS server. The DTLS client opens a secure connection on the SCTP port 4740 of the DTLS server if SCTP or PR-SCTP is selected as the transport protocol. The TLS client opens a secure connection on the TCP port 4740 of the TLS server if TCP is selected as the transport protocol. The DTLS client opens a secure connection on the UDP port 4740 of the DTLS server if UDP is selected as the transport protocol. 11.3. Authentication IPFIX Exporting Processes and IPFIX Collecting Processes are identified by the fully qualified domain name of the interface on which IPFIX Messages are sent or received, for purposes of X.509 client and server certificates as in [RFC3280]. To prevent man-in-the-middle attacks from impostor Exporting or Collecting Processes, the acceptance of data from an unauthorized Exporting Process, or the export of data to an unauthorized Collecting Process, strong mutual authentication via asymmetric keys MUST be used for both TLS and DTLS. Each of the IPFIX Exporting and Collecting Processes MUST verify the identity of its peer against its authorized certificates, and MUST verify that the peer's certificate matches its fully qualified domain name, or, in the case of SCTP, the fully qualified domain name of one of its endpoints. The fully qualified domain name used to identify an IPFIX Collecting Process or Exporting Process may be stored either in a subjectAltName extension of type dNSName, or in the most specific Common Name field of the Subject field of the X.509 certificate. If both are present, the subjectAltName extension is given preference. Internationalized domain names (IDN) in either the subjectAltName extension of type dNSName or the most specific Common Name field of the Subject field of the X.509 certificate MUST be encoded using Punycode [RFC3492] as described in Section 4 of [RFC3490], "Conversion Operations". 11.4. Protection against DoS Attacks An attacker may mount a denial-of-service (DoS) attack against an IPFIX collection system either directly, by sending large amounts of traffic to a Collecting Process, or indirectly, by generating large amounts of traffic to be measured by a Metering Process. Direct denial-of-service attacks can also involve state exhaustion, whether at the transport layer (e.g., by creating a large number of pending connections), or within the IPFIX Collecting Process itself (e.g., by sending Flow Records pending Template or scope information, a large amount of Options Template Records, etc.). SCTP mandates a cookie-exchange mechanism designed to defend against SCTP state exhaustion denial-of-service attacks. Similarly, TCP provides the "SYN cookie" mechanism to mitigate state exhaustion; SYN cookies SHOULD be used by any Collecting Process accepting TCP connections. DTLS also provides cookie exchange to protect against DTLS server state exhaustion. The reader should note that there is no way to prevent fake IPFIX Message processing (and state creation) for UDP & SCTP communication. The use of TLS and DTLS can obviously prevent the creation of fake states, but they are themselves prone to state exhaustion attacks. Therefore, Collector rate limiting SHOULD be used to protect TLS & DTLS (like limiting the number of new TLS or DTLS session per second to a sensible number). IPFIX state exhaustion attacks can be mitigated by limiting the rate at which new connections or associations will be opened by the Collecting Process, the rate at which IPFIX Messages will be accepted by the Collecting Process, and adaptively limiting the amount of state kept, particularly records waiting on Templates. These rate and state limits MAY be provided by a Collecting Process; if provided, the limits SHOULD be user configurable. Additionally, an IPFIX Collecting Process can eliminate the risk of state exhaustion attacks from untrusted nodes by requiring TLS or DTLS mutual authentication, causing the Collecting Process to accept IPFIX Messages only from trusted sources. With respect to indirect denial of service, the behavior of IPFIX under overload conditions depends on the transport protocol in use. For IPFIX over TCP, TCP congestion control would cause the flow of IPFIX Messages to back off and eventually stall, blinding the IPFIX system. PR-SCTP improves upon this situation somewhat, as some IPFIX Messages would continue to be received by the Collecting Process due to the avoidance of head-of-line blocking by SCTP's multiple streams and partial reliability features, possibly affording some visibility of the attack. The situation is similar with UDP, as some datagrams may continue to be received at the Collecting Process, effectively applying sampling to the IPFIX Message stream, implying that some forensics may be left. To minimize IPFIX Message loss under overload conditions, some mechanism for service differentiation could be used to prioritize IPFIX traffic over other traffic on the same link. Alternatively, IPFIX Messages can be transported over a dedicated network. In this case, care must be taken to ensure that the dedicated network can handle the expected peak IPFIX Message traffic. 11.5. When DTLS or TLS Is Not an Option The use of DTLS or TLS might not be possible in some cases due to performance issues or other operational concerns. Without TLS or DTLS mutual authentication, IPFIX Exporting Processes and Collecting Processes can fall back on using IP source addresses to authenticate their peers. A policy of allocating Exporting Process and Collecting Process IP addresses from specified address ranges, and using ingress filtering to prevent spoofing, can improve the usefulness of this approach. Again, completely segregating IPFIX traffic on a dedicated network, where possible, can improve security even further. In any case, the use of open Collecting Processes (those that will accept IPFIX Messages from any Exporting Process regardless of IP address or identity) is discouraged. Modern TCP and SCTP implementations are resistant to blind insertion attacks (see [RFC1948], [RFC4960]); however, UDP offers no such protection. For this reason, IPFIX Message traffic transported via UDP and not secured via DTLS SHOULD be protected via segregation to a dedicated network. 11.6. Logging an IPFIX Attack IPFIX Collecting Processes MUST detect potential IPFIX Message insertion or loss conditions by tracking the IPFIX Sequence Number, and SHOULD provide a logging mechanism for reporting out-of-sequence messages. Note that an attacker may be able to exploit the handling of out-of-sequence messages at the Collecting Process, so care should be taken in handling these conditions. For example, a Collecting Process that simply resets the expected Sequence Number upon receipt of a later Sequence Number could be temporarily blinded by deliberate injection of later Sequence Numbers. IPFIX Exporting and Collecting Processes SHOULD log any connection attempt that fails due to authentication failure, whether due to being presented an unauthorized or mismatched certificate during TLS or DTLS mutual authentication, or due to a connection attempt from an unauthorized IP address when TLS or DTLS is not in use. IPFIX Exporting and Collecting Processes SHOULD detect and log any SCTP association reset or TCP connection reset. 11.7. Securing the Collector The security of the Collector and its implementation is important to achieve overall security. However, it is outside the scope of this document. 12. IANA Considerations IPFIX Messages use two fields with assigned values. These are the IPFIX Version Number, indicating which version of the IPFIX Protocol was used to export an IPFIX Message, and the IPFIX Set ID, indicating the type for each set of information within an IPFIX Message. The IPFIX Version Number value of 10 is reserved for the IPFIX protocol specified in this document. Set ID values of 0 and 1 are not used for historical reasons [RFC3954]. The Set ID value of 2 is reserved for the Template Set. The Set ID value of 3 is reserved for the Option Template Set. All other Set ID values from 4 to 255 are reserved for future use. Set ID values above 255 are used for Data Sets. New assignments in either IPFIX Version Number or IPFIX Set ID assignments require a Standards Action [RFC2434], i.e., they are to be made via Standards Track RFCs approved by the IESG. Appendix A. IPFIX Encoding Examples This appendix, which is a not a normative reference, contains IPFIX encoding examples. Let's consider the example of an IPFIX Message composed of a Template Set, a Data Set (which contains three Data Records), an Options Template Set and a Data Set (which contains 2 Data Records related to the previous Options Template Record). IPFIX Message: +--------+------------------------------------------. . . | | +--------------+ +------------------+ |Message | | Template | | Data | | Header | | Set | | Set | . . . | | | (1 Template) | | (3 Data Records) | | | +--------------+ +------------------+ +--------+------------------------------------------. . . . . .-------------------------------------------+ +------------------+ +------------------+ | | Options | | Data | | . . . | Template Set | | Set | | | (1 Template) | | (2 Data Records) | | +------------------+ +------------------+ | . . .-------------------------------------------+ A.1. Message Header Example The Message Header is composed of: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Version = 0x000a | Length = 152 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Export Time | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Sequence Number | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Observation Domain ID | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.2. Template Set Examples A.2.1. Template Set Using IETF-Specified Information Elements We want to report the following Information Elements: - The IPv4 source IP address: sourceIPv4Address in [RFC5102], with a length of 4 octets - The IPv4 destination IP address: destinationIPv4Address in [RFC5102], with a length of 4 octets - The next-hop IP address (IPv4): ipNextHopIPv4Address in [RFC5102], with a length of 4 octets - The number of packets of the Flow: inPacketDeltaCount in [RFC5102], with a length of 4 octets - The number of octets of the Flow: inOctetDeltaCount in [RFC5102], with a length of 4 octets Therefore, the Template Set will be composed of the following: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 2 | Length = 28 octets | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID 256 | Field Count = 5 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| sourceIPv4Address = 8 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| destinationIPv4Address = 12 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| ipNextHopIPv4Address = 15 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| inPacketDeltaCount = 2 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| inOctetDeltaCount = 1 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.2.2. Template Set Using Enterprise-Specific Information Elements We want to report the following Information Elements: - The IPv4 source IP address: sourceIPv4Address in [RFC5102], with a length of 4 octets - The IPv4 destination IP address: destinationIPv4Address in [RFC5102], with a length of 4 octets - An enterprise-specific Information Element representing proprietary information, with a type of 15 and a length of 4 - The number of packets of the Flow: packetDeltaCount in [RFC5102],
EID 2892 (Verified) is as follows:

Section: multiple

Original Text:

inPacketDeltaCount

Corrected Text:

packetDeltaCount
Notes:
s/inPacketDeltaCount/packetDeltaCount/ (four times)

- in sections A.2.1 (+figure) and A.2.2 (+figure)

Per [RFC5102] and IANA's IPFIX registry, the correct name is "packetDeltaCount".
with a length of 4 octets - The number of octets of the Flow: octetDeltaCount in [RFC5102],
EID 2891 (Verified) is as follows:

Section: multiple

Original Text:

inOctetDeltaCount

Corrected Text:

octetDeltaCount
Notes:
s/inOctetDeltaCount/octetDeltaCount/ (four times)

- in sections A.2.1 (+figure) and A.2.2 (+figure)

Per [RFC5102] and IANA's IPFIX registry, the correct name is "octetDeltaCount".
with a length of 4 octets Therefore, the Template Set will be composed of the following: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 2 | Length = 32 octets | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID 257 | Field Count = 5 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| sourceIPv4Address = 8 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| destinationIPv4Address = 12 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |1| Information Element Id. = 15| Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Enterprise number | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| inPacketDeltaCount = 2 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |0| inOctetDeltaCount = 1 | Field Length = 4 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.3. Data Set Example In this example, we report the following three Flow Records: Src IP addr. | Dst IP addr. | Next Hop addr. | Packet | Octets | | | Number | Number ------------------------------------------------------------------ 192.0.2.12 | 192.0.2.254 | 192.0.2.1 | 5009 | 5344385 192.0.2.27 | 192.0.2.23 | 192.0.2.2 | 748 | 388934 192.0.2.56 | 192.0.2.65 | 192.0.2.3 | 5 | 6534 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 256 | Length = 64 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.12 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.254 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.1 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 5009 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 5344385 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.27 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.23 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.2 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 748 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 388934 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.56 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.65 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 192.0.2.3 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 5 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 6534 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Note that padding is not necessary in this example. A.4. Options Template Set Examples A.4.1. Options Template Set Using IETF-Specified Information Elements Per line card (the router being composed of two line cards), we want to report the following Information Elements: - Total number of IPFIX Messages: exportedPacketCount [RFC5102], with a length of 2 octets - Total number of exported Flows: exportedFlowCount [RFC5102], with a length of 2 octets The line card, which is represented by the lineCardId Information Element [RFC5102], is used as the Scope Field. Therefore, the Options Template Set will be: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 3 | Length = 24 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID 258 | Field Count = 3 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope Field Count = 1 |0| lineCardId = 141 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope 1 Field Length = 4 |0| exportedPacketCount = 41 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 2 |0| exportedFlowCount = 42 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 2 | Padding | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.4.2. Options Template Set Using Enterprise-Specific Information Elements Per line card (the router being composed of two line cards), we want to report the following Information Elements: - Total number of IPFIX Messages: exportedMessageTotalCount [RFC5102],
EID 2890 (Verified) is as follows:

Section: multiple

Original Text:

exportedPacketCount

Corrected Text:

exportedMessageTotalCount
Notes:
s/exportedPacketCount/exportedMessageTotalCount/ (six times)

- in sections A.4.1 (+figure), A.4.2 (+figure), and A.4.3 (+figure).

[RFC5102] defines exportedMessageTotalCount, exportedOctetTotalCount, and exportedFlowRecordTotalCount - but no "exportedPacketCount".

Presumably "exportedMessageTotalCount" is the name that's intended here.
with a length of 2 octets - An enterprise-specific number of exported Flows, with a type of 42 and a length of 4 octets The line card, which is represented by the lineCardId Information Element [RFC5102], is used as the Scope Field. The format of the Options Template Set is as follows: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 3 | Length = 28 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID 259 | Field Count = 3 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope Field Count = 1 |0| lineCardId = 141 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope 1 Field Length = 4 |0| exportedPacketCount = 41 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 2 |1|Information Element Id. = 42 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 4 | Enterprise number ... +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ ... Enterprise number | Padding | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.4.3. Options Template Set Using an Enterprise-Specific Scope In this example, we want to export the same information as in the example in Section A.4.1: - Total number of IPFIX Messages: exportedPacketCount [RFC5102], with a length of 2 octets - Total number of exported Flows: exportedFlowRecordTotalCount [RFC5102],
EID 2889 (Verified) is as follows:

Section: multiple

Original Text:

exportedFlowCount

Corrected Text:

exportedFlowRecordTotalCount
Notes:
s/exportedFlowCount/exportedFlowRecordTotalCount/ (four times)

- in sections A.4.1 (+figure), and A.4.3 (+figure).

The definition in [RFC5102] and IANA's IPFIX registry is "exportedFlowRecordTotalCount" (as correctly used elsewhere in this RFC).
with a length of 2 octets But this time, the information pertains to a proprietary scope, identified by enterprise-specific Information Element number 123. The format of the Options Template Set is now as follows: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 3 | Length = 28 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Template ID 260 | Field Count = 3 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope Field Count = 1 |1|Scope 1 Infor. El. Id. = 123 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Scope 1 Field Length = 4 | Enterprise Number ... +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ ... Enterprise Number |0| exportedPacketCount = 41 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 2 |0| exportedFlowCount = 42 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Field Length = 2 | Padding | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.4.4. Data Set Using an Enterprise-Specific Scope In this example, we report the following two Data Records: Enterprise field 123 | exportedPacketCount | exportedFlowCount ------------------------------------------------------------------- 1 | 345 | 10201 2 | 690 | 20402
EID 1655 (Verified) is as follows:

Section: A.4.4.

Original Text:

   Line Card ID               | IPFIX Message  | Exported Flow Records
   -------------------------------------------------------------------
   Line Card 1 (lineCardId=1) | 345            | 10201
   Line Card 2 (lineCardId=2) | 690            | 20402

Corrected Text:

   Enterprise field 123 | exportedPacketCount | exportedFlowCount
   -------------------------------------------------------------------
   1                    | 345                 | 10201
   2                    | 690                 | 20402
Notes:
The example in A.4.4 uses set ID 260 which is defined in the template in A.4.3.
Therefore the fields used in A.4.4 must be those defined in A.4.3.
Fortunately the field lengths are correct, so no other change is required.
0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Set ID = 260 | Length = 20 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 1 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 345 | 10201 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 2 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 690 | 20402 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.5. Variable-Length Information Element Examples A.5.1. Example of Variable-Length Information Element with Length Inferior to 255 Octets 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 5 | 5 octet Information Element | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ A.5.2. Example of Variable-Length Information Element with 3 Octet Length Encoding
EID 2792 (Verified) is as follows:

Section: A.5.2

Original Text:

A.5.2.  Example of Variable-Length Information Element with Length 255
        to 65535 Octets

Corrected Text:

A.5.2.  Example of Variable-Length Information Element with 3 Octet
        Length Encoding
Notes:
Per Erratum 2791, this section header should be changed to reflect that the 3 octet Lenght encoding supports lengths of less than 255 as well as greater than or equal to 255.

Note that there is a corresponding change in the Table of Contents
0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 255 | 1000 | IE ... | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | 1000 octet Information Element | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ : ... : +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | ... IE | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ References Normative References [RFC1305] Mills, D., "Network Time Protocol (Version 3) Specification, Implementation and Analysis", RFC 1305, March 1992. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [RFC2434] Narten, T. and H. Alvestrand, "Guidelines for Writing an IANA Considerations Section in RFCs", BCP 26, RFC 2434, October 1998. [RFC3280] Housley, R., Polk, W., Ford, W., and D. Solo, "Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile", RFC 3280, April 2002. [RFC3436] Jungmaier, A., Rescorla, E., and M. Tuexen, "Transport Layer Security over Stream Control Transmission Protocol", RFC 3436, December 2002. [RFC3758] Stewart, R., Ramalho, M., Xie, Q., Tuexen, M., and P. Conrad, "Stream Control Transmission Protocol (SCTP) Partial Reliability Extension", RFC 3758, May 2004. [RFC4346] Dierks, T. and E. Rescorla, "The Transport Layer Security (TLS) Protocol Version 1.1", RFC 4346, April 2006. [RFC4347] Rescorla, E. and N. Modadugu, "Datagram Transport Layer Security", RFC 4347, April 2006. [RFC3490] Faltstrom, P., Hoffman, P., and A. Costello, "Internationalizing Domain Names in Applications (IDNA)", RFC 3490, March 2003. [RFC3492] Costello, A., "Punycode: A Bootstring encoding of Unicode for Internationalized Domain Names in Applications (IDNA)", RFC 3492, March 2003. [RFC4960] Stewart, R., Ed., "Stream Control Transmission Protocol", RFC 4960, September 2007. [RFC5102] Quittek, J., Bryant S., Claise, B., Aitken, P., and J. Meyer, "Information Model for IP Flow Information Export", RFC 5102, January 2008. [TCP] Postel, J., "Transmission Control Protocol", STD 7, RFC 793, September 1981. [UDP] Postel, J., "User Datagram Protocol", STD 6, RFC 768, August 1980. Informative References [IPFIX-ARCH] Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek, "Architecture Model for IP Flow Information Export", Work in Progress, September 2006. [IPFIX-AS] Zseby, T., Boschi, E., Brownlee, N., and B. Claise, "IPFIX Applicability", Work in Progress, June 2007. [PEN] IANA Private Enterprise Numbers registry http://www.iana.org/assignments/enterprise-numbers. [RFC1948] Bellovin, S., "Defending Against Sequence Number Attacks", RFC 1948, May 1996. [RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC3917] Quittek, J., Zseby, T., Claise, B., and S. Zander, "Requirements for IP Flow Information Export (IPFIX)", RFC 3917, October 2004. [RFC3550] Schulzrinne, H., Casner, S., Frederick, R., and V. Jacobson, "RTP: A Transport Protocol for Real-Time Applications", STD 64, RFC 3550, July 2003. [RFC3954] Claise, B., Ed., "Cisco Systems NetFlow Services Export Version 9", RFC 3954, October 2004. [IEEE.754.1985] Institute of Electrical and Electronics Engineers, "Standard for Binary Floating-Point Arithmetic", IEEE Standard 754, August 1985. [dtls-for-sctp] Tuexen, M. and E. Rescola, "Datagram Transport Layer Security for Stream Control Transmission Protocol", Work in Progress, November 2007. Acknowledgments We would like to thank the following persons: Ganesh Sadasivan for his significant contribution during the initial phases of the protocol specification; Juergen Quittek for the coordination job within IPFIX and PSAMP; Nevil Brownlee, Dave Plonka, Paul Aitken, and Andrew Johnson for the thorough reviews; Randall Stewart and Peter Lei for their SCTP expertise and contributions; Martin Djernaes for the first essay on the SCTP section; Michael Behringer and Eric Vyncke for their advice and knowledge in security; Michael Tuexen for his help regarding the DTLS section; Elisa Boschi for her contribution regarding the improvement of SCTP sections; Mark Fullmer, Sebastian Zander, Jeff Meyer, Maurizio Molina, Carter Bullard, Tal Givoly, Lutz Mark, David Moore, Robert Lowe, Paul Calato, and many more, for the technical reviews and feedback. Authors' Addresses Benoit Claise Cisco Systems De Kleetlaan 6a b1 1831 Diegem Belgium Phone: +32 2 704 5622 EMail: bclaise@cisco.com Stewart Bryant Cisco Systems, Inc. 250, Longwater, Green Park, Reading, RG2 6GB, United Kingdom Phone: +44 (0)20 8824-8828 EMail: stbryant@cisco.com Simon Leinen SWITCH Werdstrasse 2 P.O. Box CH-8021 Zurich Switzerland Phone: +41 44 268 1536 EMail: simon.leinen@switch.ch Thomas Dietz NEC Europe Ltd. NEC Laboratories Europe Network Research Division Kurfuersten-Anlage 36 69115 Heidelberg Germany Phone: +49 6221 4342-128 EMail: Thomas.Dietz@nw.neclab.eu Brian H. Trammell CERT Network Situational Awareness Software Engineering Institute 4500 Fifth Avenue Pittsburgh, PA 15213 United States Phone: +1 412 268 9748 EMail: bht@cert.org Full Copyright Statement Copyright (C) The IETF Trust (2008). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf-ipr@ietf.org.
EID 1818 (Verified) is as follows:

Section: All

Original Text:

None

Corrected Text:

None
Notes:
Throughout the document, all instances of "Option Template" must be replaced by "Options Template"